EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation

Miaomiao Yang iD, Yongqing Ma, Wenli Han, Zhe Qu iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0304091 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Miaomiao Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Implantation, Dalian Stomatological Hosipital, Dalian City, Liaoning Province, China. Hauptthemen laut MEDLINE: Sinus Floor Augmentation, Maxillary Sinus. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Science Research Program Project (Dengfeng Program) of Dalian Stomatological Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To date, it remains a challenge to conduct maxillary sinus floor elevation (MSFE) owing to heterogeneity of anatomical structures and limited operative visibility of the maxillary sinus. The aim of this study is to investigate the safety of MSFE and the accuracy of implant placement using dynamic navigation.

Methods

Forty-two implants were placed in thirty-five patients requiring implantation in posterior maxilla with dynamic navigation. They were assigned to either lateral window sinus floor elevation (LWSFE) group (n = 22) or transcrestal sinus floor elevation (TSFE) group (n = 20) according to the residual alveolar bone height (RBH). Platform deviation, apex deviation and angular deviation between actual and planned implant placement were measured in precision evaluation software. Three deviations of two groups were compared via SPSS 22.0 software.

Results

Neither accidental bleeding nor perforation of Schneiderian membrane occurred in any patients. The actual window position of LWSFE was consistent with the preoperative design. There were no significant differences in platform, apex and angular deviations between the two groups (P > 0.05).

Conclusion

In this study the dynamic navigation harvested clinically acceptable safety of MSFE and accuracy for implant placement in posterior maxillary region. The dynamic navigation would provide the clinician with assistance in achieving precise preoperative planning and reducing complications in surgical procedures. The granular bone grafts used in the LWSFE did not significantly affection on the accuracy of the simultaneous implant placement under the guidance of dynamic navigation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sinus Floor AugmentationMaxillary SinusHumansMaleFemaleMiddle AgedAdultAgedDental ImplantsDental Implantation, EndosseousMaxillaSurgery, Computer-Assisted

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Implantation, Dalian Stomatological Hosipital, Dalian City, Liaoning Province, China.
  • Department of Oral and Maxillofacial Surgery, Dalian Stomatological Hosipital, Dalian City, Liaoning Province, China.
  • Radiological department Dalian Stomatological Hosipital, Dalian City, Liaoning Province, China.

ORCID-Profile: Miaomiao Yang, Zhe Qu

Förderung

  • Medical Science Research Program Project (Dengfeng Program) of Dalian Stomatological Hospital

Zitieren

APA

Yang, M., Ma, Y., Han, W., & Qu, Z. (2024). The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation. PLOS ONE. https://doi.org/10.1371/journal.pone.0304091

Vancouver

Yang M, Ma Y, Han W, Qu Z. The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation. PLOS ONE. 2024. doi:10.1371/journal.pone.0304091

BibTeX
@article{Yang2024,
  author = {Yang, Miaomiao and Ma, Yongqing and Han, Wenli and Qu, Zhe},
  title = {The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0304091}
}
Kostenlos starten →