Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0303152 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift PLOS ONE, 2024. Verfasst von Emilio Jiménez-Martínez und 7 weiteren Autor:innen. Beteiligte Einrichtung: Infectious Disease Department, Bellvitge University Hospital, L'Hospitalet de Llobregat (Barcelona), Barcelona, Spain. Hauptthemen laut MEDLINE: Catheterization, Peripheral. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Instituto de Salud Carlos III, Departament de Recerca i Universitats de la Generalitat de Catalunya – AGAUR.
Abstract (Originalsprache)
Introduction
Short peripheral intravenous catheter (PIVC) failure is a common complication that is generally underdiagnosed. Some studies have evaluated the factors associated with these complications, but the impact of care complexity individual factors and nurse staffing levels on PIVC failure is still to be assessed. The aim of this study was to determine the incidence and risk factors of PIVC failure in the public hospital system of the Southern Barcelona Metropolitan Area.
Methods
A retrospective multicentre observational cohort study of hospitalised adult patients was conducted in two public hospitals in Barcelona from 1 st January 2016 to 31 st December 2017. All adult patients admitted to the hospitalisation ward were included until the day of discharge. Patients were classified according to presence or absence of PIVC failure. The main outcomes were nurse staffing coverage (ATIC patient classification system) and 27-care complexity individual factors. Data were obtained from electronic health records in 2022.
Results
Of the 44,661 patients with a PIVC, catheter failure was recorded in 2,624 (5.9%) patients (2,577 [5.8%] phlebitis and 55 [0.1%] extravasation). PIVC failure was more frequent in female patients (42%), admitted to medical wards, unscheduled admissions, longer catheter dwell time (median 7.3 vs 2.2 days) and those with lower levels of nurse staffing coverage (mean 60.2 vs 71.5). Multivariate logistic regression analysis revealed that the female gender, medical ward admission, catheter dwell time, haemodynamic instability, uncontrolled pain, communication disorders, a high risk of haemorrhage, mental impairments, and a lack of caregiver support were independent factors associated with PIVC failure. Moreover, higher nurse staffing were a protective factor against PIVC failure (AUC, 0.73; 95% confidence interval [CI]: 0.72–0.74).
Conclusion
About 6% of patients presented PIVC failure during hospitalisation. Several complexity factors were associated with PIVC failure and lower nurse staffing levels were identified in patients with PIVC failure. Institutions should consider that prior identification of care complexity individual factors and nurse staffing coverage could be associated with a reduced risk of PIVC failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Infectious Disease Department, Bellvitge University Hospital, L'Hospitalet de Llobregat (Barcelona), Barcelona, Spain.
- Medicine and Health Science Faculty, School of Nursing, University of Barcelona, L'Hospitalet de Llobregat (Barcelona), Barcelona, Spain.
- Bellvitge Institute of Biomedical Research, IDIBELL, Nursing Research Group, Barcelona, Spain.
- Nursing Knowledge Management and Information Systems Department, Bellvitge University Hospital, L'Hospitalet de Llobregat (Barcelona), Barcelona, Spain.
- Nursing Knowledge Management and Information Systems Department, Viladecans Hospital, Viladecans (Barcelona), Barcelona, Spain.
- Catalan Institute of Health, Barcelona, Spain.
ORCID-Profile: Emilio Jiménez-Martínez
Förderung
- Instituto de Salud Carlos III
- Departament de Recerca i Universitats de la Generalitat de Catalunya – AGAUR
Zitieren
APA
Jiménez-Martínez, E., Adamuz, J., González-Samartino, M., Muñoz-Carmona, M. A., Hornero, A., Martos-Martínez, M. P., Membrive-Martínez, R., & Juvé-Udina, M. E. (2024). Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study. PLOS ONE. https://doi.org/10.1371/journal.pone.0303152
Vancouver
Jiménez-Martínez E, Adamuz J, González-Samartino M, Muñoz-Carmona MA, Hornero A, Martos-Martínez MP, et al. Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study. PLOS ONE. 2024. doi:10.1371/journal.pone.0303152
BibTeX
@article{JimnezMartnez2024,
author = {Jiménez-Martínez, Emilio and Adamuz, Jordi and González-Samartino, Maribel and Muñoz-Carmona, Maria Antonia and Hornero, Ana and Martos-Martínez, M Purificacion and Membrive-Martínez, Remedios and Juvé-Udina, Maria-Eulàlia},
title = {Peripheral intravenous catheter failure, nurse staffing levels and care complexity individual factors: A retrospective multicentre cohort study},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0303152}
}
EUVIMED