Application of near-infrared spectroscopy to assess the effect of the cupping size on the spatial hemodynamic response from the area inside and outside the cup of the biceps
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0302828 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Pu-Chun Mo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America. Hauptthemen laut MEDLINE: Spectroscopy, Near-Infrared, Hemodynamics, Muscle, Skeletal, Oxyhemoglobins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under −300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin ( P = 0.039) but no interaction in oxyhemoglobin ( P = 0.100), and a main effect of the cup size ( P = 0.001) and location ( P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 μM) compared to the 40-mm (2.095±0.312 μM, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America.
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
- Department of Physical Therapy, National Cheng Kung University, Tainan, Taiwan.
- Department of Biomedical and Translational Science, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America.
- Department of Neurosurgery, Chi Mei Hospital Chiali, Tainan, Taiwan.
- Department of Nursing, Chung Hwa University of Medical Technology, Tainan, Taiwan.
ORCID-Profile: Pu-Chun Mo, Cheng-Feng Lin, Yih-Kuen Jan
Zitieren
APA
Mo, P. C., Lin, C. F., Li, Y., Hernandez, M. E., Liao, J. C., Hung, I. Y., & Jan, Y. K. (2024). Application of near-infrared spectroscopy to assess the effect of the cupping size on the spatial hemodynamic response from the area inside and outside the cup of the biceps. PLOS ONE. https://doi.org/10.1371/journal.pone.0302828
Vancouver
Mo PC, Lin CF, Li Y, Hernandez ME, Liao JC, Hung IY, et al. Application of near-infrared spectroscopy to assess the effect of the cupping size on the spatial hemodynamic response from the area inside and outside the cup of the biceps. PLOS ONE. 2024. doi:10.1371/journal.pone.0302828
BibTeX
@article{Mo2024,
author = {Mo, Pu-Chun and Lin, Cheng-Feng and Li, Yameng and Hernandez, Manuel E and Liao, Jen-Chieh and Hung, Isabella Yu-Ju and Jan, Yih-Kuen},
title = {Application of near-infrared spectroscopy to assess the effect of the cupping size on the spatial hemodynamic response from the area inside and outside the cup of the biceps},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0302828}
}
EUVIMED