An improved diagnostic method for taurodontism and a comparative study on its effectiveness evaluation
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0302810 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Yunmeng Da und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prothodontics, Hebei Eye Hosipital, Hebei Provincial Key Laboratory of Ophthalmology, Hebei Clinical Medical Research Center of Eye Dis…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Xingtai Science and Technology Project.
Abstract (Originalsprache)
Objective
The two commonly used diagnostic methods for taurodontism are susceptible to aging changes, mastication wear and other factors. Therefore, this study proposed an improved diagnostic method for taurodontism, and compared it with the previous two methods as a supplement for taurodontism diagnosis.
Methods
The included patients were aged 10–89 years and admitted to the Department of Stomatology of Hebei Eye Hospital from June 1, 2022 to May 31, 2023. Eighty cone-beam computed tomography images were divided equally into 4 groups: 10–29, 30–49, 50–69, and 70–89 years old. The right mandibular first molars were selected as measurement objects. Firstly, |BD| and taurodontism index (TI)-related parameters were measured using Shifman and Chanannel’s method and crown-body(CB) and root (R) lengths was measured by Seow and Lai’s method. The improved method used the length from the cementoenamel junction(CEJ) to the root bifurcation point(body, B)and the root length(root, R)as the measurement objects. Finally, TI, CB/R ratios, and B/R ratios were calculated according to the formulas given below. One-way ANOVA analysis was mainly used to compare the differences in the values, indices and ratios of taurodontism among different age groups (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Prothodontics, Hebei Eye Hosipital, Hebei Provincial Key Laboratory of Ophthalmology, Hebei Clinical Medical Research Center of Eye Diseases, Xingtai, Hebei, China.
- Department of Oral and Maxillofacial Surgery, Hebei Eye Hosipital, Hebei Provincial Key Laboratory of Ophthalmology, Hebei Clinical Medical Research Center of Eye Diseases, Xingtai, Hebei, China.
ORCID-Profile: Yunmeng Da
Förderung
- Xingtai Science and Technology Project
Zitieren
APA
Da, Y., Zhang, L., Chai, Z., Du, H., Hao, L., Zhang, L., Zhang, Z., & Shen, Y. (2024). An improved diagnostic method for taurodontism and a comparative study on its effectiveness evaluation. PLOS ONE. https://doi.org/10.1371/journal.pone.0302810
Vancouver
Da Y, Zhang L, Chai Z, Du H, Hao L, Zhang L, et al. An improved diagnostic method for taurodontism and a comparative study on its effectiveness evaluation. PLOS ONE. 2024. doi:10.1371/journal.pone.0302810
BibTeX
@article{Da2024,
author = {Da, Yunmeng and Zhang, Le and Chai, Zhihong and Du, Hongfang and Hao, Lele and Zhang, Li and Zhang, Zhiyin and Shen, Yongfan},
title = {An improved diagnostic method for taurodontism and a comparative study on its effectiveness evaluation},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0302810}
}