Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 11.07.2024. Verfasst von Nacer Badi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Thermal Management and Sustainable Research Laboratory, Department of Physics, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia. Hauptthemen laut MEDLINE: Convection. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Tabuk.
Abstract (Originalsprache)
In hot dry regions, photovoltaic modules are exposed to excessive temperatures, which leads to a drop in performance and the risk of overheating. The present numerical study aims to evaluate the natural air cooling of PV modules by an inclined chimney mounted at the back. The basic equations were solved using the finite volume method. The validity of the model is verified by comparison with the data available in the literature. Thermal and dynamic flow patterns are analyzed for a variety of parameters: Rayleigh numbers from 10 2 to 10 6 , PV panel tilt angle from 15° to 90°, and channel aspect ratios from 1/20 to 1/5. A critical aspect ratio has been determined to minimize overheating of the PV module. According to the computational results, the tilt angle and modified Rayleigh number increase the mass flow rate and mean Nusselt number. The overheating zone with maximum temperatures is located in the upper part of the photovoltaic panel. The addition of an extension to both channel’s inlet and outlet was found to improve the cooling of the photovoltaic panels; however, only the extensions downstream of the channel are truly effective. The critical lengths at which channel performance improves significantly were identified by examining the impact of longer extensions on channel performance. Increasing the extension length from 0 to 3H improves the mass flow rate by 65%, the average Nusselt number by 13.4%, and leads to an 11% decrease in maximum temperature when Ra* = 10 6 . This cooling technique is particularly promising for hot dry regions where water is scarce.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Thermal Management and Sustainable Research Laboratory, Department of Physics, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia.
- Renewable Energy and Environmental Technologies Research Center, University of Tabuk, Tabuk, Saudi Arabia.
- Laboratory of Energetics and Thermal and Mass Transfer (LR01ES07), Faculty of Sciences of Tunis, University of Tunis El Manar, Tunis, Tunisia.
- Department of Physics, Faculty of Sciences of Bizerte, University of Carthage, Jarzouna, Tunisia.
ORCID-Profile: Nacer Badi
Förderung
- University of Tabuk
Zitieren
APA
Badi, N., & Laatar, A. H. (2024). Improved cooling of photovoltaic panels by natural convection flow in a channel with adiabatic extensions. PLOS ONE, 19(7), e0302326. https://doi.org/10.1371/journal.pone.0302326
Vancouver
Badi N, Laatar AH. Improved cooling of photovoltaic panels by natural convection flow in a channel with adiabatic extensions. PLOS ONE. 2024;19(7):e0302326. doi:10.1371/journal.pone.0302326
BibTeX
@article{Badi2024,
author = {Badi, Nacer and Laatar, Ali Hatem},
title = {Improved cooling of photovoltaic panels by natural convection flow in a channel with adiabatic extensions},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {7},
pages = {e0302326},
doi = {10.1371/journal.pone.0302326}
}
EUVIMED