Effect of systemic vascular resistance on the agreement between stroke volume by non-invasive pulse wave analysis and Doppler ultrasound in healthy volunteers
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0302159 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Sole Lindvåg Lie und 3 weiteren Autor:innen. Beteiligte Einrichtung: Norwegian Air Ambulance Foundation, Department of Research and Development, Oslo, Norway. Hauptthemen laut MEDLINE: Vascular Resistance, Ultrasonography, Doppler, Stroke Volume, Pulse Wave Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Background
Stroke volume can be estimated beat-to-beat and non-invasively by pulse wave analysis (PWA). However, its reliability has been questioned during marked alterations in systemic vascular resistance (SVR). We studied the effect of SVR on the agreement between stroke volume by PWA and Doppler ultrasound during reductions in stroke volume in healthy volunteers.
Methods
In a previous study we simultaneously measured stroke volume by PWA (SV PWA ) and suprasternal Doppler ultrasound (SV US ). We exposed 16 healthy volunteers to lower body negative pressure (LBNP) to reduce stroke volume in combination with isometric hand grip to elevate SVR. LBNP was increased by 20 mmHg every 6 minutes from 0 to 80 mmHg, or until hemodynamic decompensation. The agreement between SV PWA and SV US was examined using Bland-Altman analysis with mixed regression. Within-subject limits of agreement (LOA) was calculated from the residual standard deviation. SVR US was calculated from SV US . We allowed for a sloped bias line by introducing the mean of the methods and SVR US as explanatory variables to examine whether the agreement was dependent on the magnitude of stroke volume and SVR US .
Results
Bias ± limits of agreement (LOA) was 27.0 ± 30.1 mL. The within-subject LOA was ±11.1 mL. The within-subject percentage error was 14.6%. The difference between methods decreased with higher means of the methods (-0.15 mL/mL, confidence interval (CI): -0.19 to -0.11, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Norwegian Air Ambulance Foundation, Department of Research and Development, Oslo, Norway.
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
- Section of Vascular Investigations, Oslo University Hospital, Oslo, Norway.
- Air Ambulance Department, Division of Prehospital Services, Oslo University Hospital, Oslo, Norway.
- Department of Anesthesia and Intensive Care Medicine, Division of Emergencies and Critical Care, Oslo University Hospital, Oslo, Norway.
ORCID-Profile: Sole Lindvåg Lie
Zitieren
APA
Lie, S. L., Hisdal, J., Rehn, M., & Høiseth, L. Ø. (2024). Effect of systemic vascular resistance on the agreement between stroke volume by non-invasive pulse wave analysis and Doppler ultrasound in healthy volunteers. PLOS ONE. https://doi.org/10.1371/journal.pone.0302159
Vancouver
Lie SL, Hisdal J, Rehn M, Høiseth LØ. Effect of systemic vascular resistance on the agreement between stroke volume by non-invasive pulse wave analysis and Doppler ultrasound in healthy volunteers. PLOS ONE. 2024. doi:10.1371/journal.pone.0302159
BibTeX
@article{Lie2024,
author = {Lie, Sole Lindvåg and Hisdal, Jonny and Rehn, Marius and Høiseth, Lars Øivind},
title = {Effect of systemic vascular resistance on the agreement between stroke volume by non-invasive pulse wave analysis and Doppler ultrasound in healthy volunteers},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0302159}
}
EUVIMED