EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia

Arkasha Sadhewa iD, Lydia V Panggalo, Illene Nanine, Ric N Price, Kamala Thriemer, Ari W Satyagraha, Benedikt Ley iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0301506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Arkasha Sadhewa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Global and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Northern Territory, Australia. Hauptthemen laut MEDLINE: Glucosephosphate Dehydrogenase Deficiency, Malaria, Vivax. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australia-Indonesia Institute, Charles Darwin International PhD Scholarships.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The WHO recommends routine testing of G6PD activity to guide radical cure in patients with Plasmodium vivax malaria. Females may have intermediate G6PD enzyme activity and to date, only complex diagnostics are able to reliably identify them. The semi-quantitative G6PD diagnostic “One Step G6PD Test” (Humasis, RoK; “RDT”) is a lateral flow assay that can distinguish deficient, intermediate, and normal G6PD status and offers a simpler diagnostic alternative.

Methods

G6PD status of participants enrolled in Malinau and Nunukan Regencies and the capital Jakarta was assessed with the RDT, and G6PD activity was measured in duplicate by reference spectrophotometry. The adjusted male median (AMM) of the spectrophotometry measurements was defined as 100% activity; 70% and 30% of the AMM were defined as thresholds for intermediate and deficient G6PD status, respectively. Results were compared to those derived from spectrophotometry at the clinically relevant G6PD activity thresholds of 30% and 70%.

Results

Of the 161 participants enrolled, 10 (6.2%) were G6PD deficient and 12 (7.5%) had intermediate G6PD activity by spectrophotometry. At the 30% threshold, the sensitivity of the RDT was 10.0% (95%CI: 0.3–44.5%) with a specificity of 99.3% (95%CI: 96.4–100.0%); the positive predictive value was 50.0% (95%CI: 1.3–98.7%) and the negative predictive value 94.3% (95%CI: 89.5–97.4%). The corresponding figures at the 70% threshold were 22.7% (95%CI: 7.8–45.4%), 100.0% (95%CI: 97.4–100.0%), 100.0% (95%CI: 47.8–100.0%) and 89.1% (95%CI: 83.1–93.5%), respectively.

Conclusion

While there is a dire need for an easy-to-use, economical, semi-quantitative diagnostic for the point of care, the observed performance of the “One Step G6PD Test” in its current form was insufficient to guide antimalarial treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glucosephosphate Dehydrogenase DeficiencyMalaria, VivaxHumansFemaleIndonesiaMaleAdultAdolescentMiddle AgedYoung AdultPoint-of-Care SystemsChildGlucosephosphate DehydrogenaseSpectrophotometrySensitivity and Specificity

Substanzen

Glucosephosphate Dehydrogenase

Autor:innen und Institutionen

  • Global and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Northern Territory, Australia.
  • EXEINS Health Initiative, Jakarta, Indonesia.
  • Mahidol-Oxford Tropical Medicine Research Unit (MORU), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand.
  • Centre for Tropical Medicine and Global Health, Nuffield Department of Clinical Medicine, University of Oxford, Oxford, United Kingdom.
  • Eijkman Research Center for Molecular Biology, National Research and Innovation Agency, Cibinong, Indonesia.
  • Division of Education, Menzies School of Health Research and Charles Darwin University, Darwin, Northern Territory, Australia.

ORCID-Profile: Arkasha Sadhewa, Benedikt Ley

Förderung

  • Australia-Indonesia Institute
  • Charles Darwin International PhD Scholarships

Zitieren

APA

Sadhewa, A., Panggalo, L. V., Nanine, I., Price, R. N., Thriemer, K., Satyagraha, A. W., & Ley, B. (2024). Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia. PLOS ONE. https://doi.org/10.1371/journal.pone.0301506

Vancouver

Sadhewa A, Panggalo LV, Nanine I, Price RN, Thriemer K, Satyagraha AW, et al. Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia. PLOS ONE. 2024. doi:10.1371/journal.pone.0301506

BibTeX
@article{Sadhewa2024,
  author = {Sadhewa, Arkasha and Panggalo, Lydia V and Nanine, Illene and Price, Ric N and Thriemer, Kamala and Satyagraha, Ari W and Ley, Benedikt},
  title = {Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0301506}
}
Kostenlos starten →