Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement
PLOS ONE · 2025
DOI: 10.1371/journal.pone.0300161 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Joseph Warwick und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Surgery & Interventional Science, Institute of Sport Exercise and Health, University College London, London, United Kingdom. Hauptthemen laut MEDLINE: Firearms, Exercise Test, Cardiorespiratory Fitness, Law Enforcement. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Law Enforcement Service.
Abstract (Originalsprache)
Objectives
Law enforcement agencies require minimum fitness standards to safeguard their officers and training staff. Firearms instructors (FI) are expected to maintain the same standards as their operational counterparts. This study aimed to quantify the daily physiological demands placed on FI.
Methods
19 FI (45 ± 5 years) completed occupational tasks whilst wearing heart rate (HR) monitors for a minimum 10 days. Maximal oxygen consumption (VO 2 max) testing was conducted on FI during a treadmill test (TT) and a multistage shuttle test (ST). Linear regression models were used to model the relationship between VO 2 and HR throughout the TT. This model was applied to HR data from occupational tasks to infer oxygen consumption. Repeated Measures ANOVAs were used to compare time spent in VO 2 max equivalent zones throughout.
Results
The VO 2 max achieved during ST (45.1 ± 5.6 ml/kg/min) was significantly higher than TT (39 ± 3 ml/kg/min) (p = 0.014). Time to exhaustion (TTE) was sooner on ST (06:26 min) compared to TT (13:16 min) (p < .001). FI spent ~85% of occupational time with an oxygen demand ≤20 ml/kg/min (p < .005). The most intense occupational tasks saw FI achieve VO 2 max ≥30 ml/kg/min, but 40 ml/kg/min. To safeguard FI from occupational-related cardiorespiratory or long-term health issues, it is intuitive to suggest fitness standards should exceed a VO 2 max of 40 ml/kg/min.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Surgery & Interventional Science, Institute of Sport Exercise and Health, University College London, London, United Kingdom.
ORCID-Profile: Joseph Warwick
Förderung
- British Law Enforcement Service
Zitieren
APA
Warwick, J., Cooper, S., & Ronca, F. (2025). Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement. PLOS ONE. https://doi.org/10.1371/journal.pone.0300161
Vancouver
Warwick J, Cooper S, Ronca F. Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement. PLOS ONE. 2025. doi:10.1371/journal.pone.0300161
BibTeX
@article{Warwick2025,
author = {Warwick, Joseph and Cooper, Sophie and Ronca, Flaminia},
title = {Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement},
journal = {PLOS ONE},
year = {2025},
doi = {10.1371/journal.pone.0300161}
}
EUVIMED