Analyses of plasma metabolites using a high performance four-channel CIL LC-MS method and identification of metabolites associated with enteric methane emissions in beef cattle
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0299268 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Hongwei Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Diet, Methane. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alberta Agriculture and Forestry, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.
Abstract (Originalsprache)
Reducing enteric methane (one greenhouse gas) emissions from beef cattle not only can be beneficial in reducing global warming, but also improve efficiency of nutrient utilization in the production system. However, direct measurement of enteric methane emissions on individual cattle is difficult and expensive. The objective of this study was to detect plasma metabolites that are associated with enteric methane emissions in beef cattle. Average enteric methane emissions (CH 4 ) per day (AVG_DAILYCH4) for each individual cattle were measured using the GreenFeed emission monitoring (GEM) unit system, and beef cattle with divergent AVG_DAILYCH4 from Angus (n = 10 for the low CH 4 group and 9 for the high CH 4 group), Charolais (n = 10 for low and 10 for = high), and Kinsella Composite (n = 10 for low and 10 for high) populations were used for plasma metabolite quantification and metabolite-CH 4 association analyses. Blood samples of these cattle were collected near the end of the GEM system tests and a high performance four-channel chemical isotope labeling (CIL) liquid chromatography (LC) mass spectrometer (MS) method was applied to identify and quantify concentrations of metabolites. The four-channel CIL LC-MS method detected 4235 metabolites, of which 1105 were found to be significantly associated with AVG_DAILYCH4 by a t-test, while 1305 were significantly associated with AVG_DAILYCH4 by a regression analysis at p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada.
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada.
- Lacombe Research and Development Centre, Agriculture and Agri-Food Canada, Lacombe, Alberta, Canada.
- Department of Animal Science and Aquaculture, Faculty of Agriculture, Dalhousie University, Truro, Nova Scotia, Canada.
ORCID-Profile: Ghader Manafiazar, Carolyn Fitzsimmons
Förderung
- Alberta Agriculture and Forestry
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
- Genome Canada
- Alberta Innovates
Zitieren
APA
Li, H., Wang, X., Vinsky, M., Manafiazar, G., Fitzsimmons, C., Li, L., & Li, C. (2024). Analyses of plasma metabolites using a high performance four-channel CIL LC-MS method and identification of metabolites associated with enteric methane emissions in beef cattle. PLOS ONE. https://doi.org/10.1371/journal.pone.0299268
Vancouver
Li H, Wang X, Vinsky M, Manafiazar G, Fitzsimmons C, Li L, et al. Analyses of plasma metabolites using a high performance four-channel CIL LC-MS method and identification of metabolites associated with enteric methane emissions in beef cattle. PLOS ONE. 2024. doi:10.1371/journal.pone.0299268
BibTeX
@article{Li2024,
author = {Li, Hongwei and Wang, Xiaohang and Vinsky, Michael and Manafiazar, Ghader and Fitzsimmons, Carolyn and Li, Liang and Li, Changxi},
title = {Analyses of plasma metabolites using a high performance four-channel CIL LC-MS method and identification of metabolites associated with enteric methane emissions in beef cattle},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0299268}
}
EUVIMED