Electric pulse exposure reduces AAV8 dosage required to transduce HepG2 cells
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0298866 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Yizhou Yao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, United States of America. Hauptthemen laut MEDLINE: Dependovirus, Green Fluorescent Proteins, Genetic Vectors, Transduction, Genetic. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
We demonstrate that applying electric field pulses to hepatocytes, in vitro, in the presence of enhanced green fluorescent protein (EGFP)-expressing adeno-associated virus (AAV8) vectors reduces the viral dosage required for a given transduction level by more than 50-fold, compared to hepatocytes exposed to AAV8-EGFP vectors without electric field pulse exposure. We conducted 48 experimental observations across 8 exposure conditions in standard well plates. The electric pulse exposures involved single 80-ms pulses with 375 V/cm field intensity. Our study suggests that electric pulse exposure results in enhanced EGFP expression in cells, indicative of increased transduction efficiency. The enhanced transduction observed in our study, if translated successfully to an in vivo setting, would be a promising indication of potential reduction in the required dose of AAV vectors. Understanding the effects of electric field pulses on AAV transduction in vitro is an important preliminary step.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, United States of America.
- Translational Core Laboratory, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, United States of America.
ORCID-Profile: Yizhou Yao
Zitieren
APA
Yao, Y., Holdcraft, R. W., Hagness, S. C., & Booske, J. H. (2024). Electric pulse exposure reduces AAV8 dosage required to transduce HepG2 cells. PLOS ONE. https://doi.org/10.1371/journal.pone.0298866
Vancouver
Yao Y, Holdcraft RW, Hagness SC, Booske JH. Electric pulse exposure reduces AAV8 dosage required to transduce HepG2 cells. PLOS ONE. 2024. doi:10.1371/journal.pone.0298866
BibTeX
@article{Yao2024,
author = {Yao, Yizhou and Holdcraft, Robert W and Hagness, Susan C and Booske, John H},
title = {Electric pulse exposure reduces AAV8 dosage required to transduce HepG2 cells},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0298866}
}
EUVIMED