Intensity scaling of conventional brain magnetic resonance images avoiding cerebral reference regions: A systematic review
PLOS ONE · 14.03.2024 · 19 (3) · e0298642
DOI: 10.1371/journal.pone.0298642 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift PLOS ONE, online erschienen am 14.03.2024. Verfasst von Tun Wiltgen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, School of Medicine, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, National Institutes of Health, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Background
Conventional brain magnetic resonance imaging (MRI) produces image intensities that have an arbitrary scale, hampering quantification. Intensity scaling aims to overcome this shortfall. As neurodegenerative and inflammatory disorders may affect all brain compartments, reference regions within the brain may be misleading. Here we summarize approaches for intensity scaling of conventional T1-weighted (w) and T2w brain MRI avoiding reference regions within the brain.
Methods
Literature was searched in the databases of Scopus, PubMed, and Web of Science. We included only studies that avoided reference regions within the brain for intensity scaling and provided validating evidence, which we divided into four categories: 1) comparative variance reduction, 2) comparative correlation with clinical parameters, 3) relation to quantitative imaging, or 4) relation to histology.
Results
Of the 3825 studies screened, 24 fulfilled the inclusion criteria. Three studies used scaled T1w images, 2 scaled T2w images, and 21 T1w/T2w-ratio calculation (with double counts). A robust reduction in variance was reported. Twenty studies investigated the relation of scaled intensities to different types of quantitative imaging. Statistically significant correlations with clinical or demographic data were reported in 8 studies. Four studies reporting the relation to histology gave no clear picture of the main signal driver of conventional T1w and T2w MRI sequences.
Conclusions
T1w/T2w-ratio calculation was applied most often. Variance reduction and correlations with other measures suggest a biologically meaningful signal harmonization. However, there are open methodological questions and uncertainty on its biological underpinning. Validation evidence on other scaling methods is even sparser.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Neurology, School of Medicine, Technical University of Munich, Munich, Germany.
- TUM-Neuroimaging Center, School of Medicine, Technical University of Munich, Munich, Germany.
- Department of Neuroscience and Biomedical Engineering, Aalto University Helsinki, Espoo, Finland.
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States of America.
- Department of Neuroradiology, School of Medicine, Technical University of Munich, Munich, Germany.
ORCID-Profile: Tun Wiltgen
Förderung
- NINDS NIH HHS
- National Institutes of Health
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Wiltgen, T., Voon, C., Van Leemput, K., Wiestler, B., & Mühlau, M. (2024). Intensity scaling of conventional brain magnetic resonance images avoiding cerebral reference regions: A systematic review. PLOS ONE, 19(3), e0298642. https://doi.org/10.1371/journal.pone.0298642
Vancouver
Wiltgen T, Voon C, Van Leemput K, Wiestler B, Mühlau M. Intensity scaling of conventional brain magnetic resonance images avoiding cerebral reference regions: A systematic review. PLOS ONE. 2024;19(3):e0298642. doi:10.1371/journal.pone.0298642
BibTeX
@article{Wiltgen2024,
author = {Wiltgen, Tun and Voon, Cuici and Van Leemput, Koen and Wiestler, Benedikt and Mühlau, Mark},
title = {Intensity scaling of conventional brain magnetic resonance images avoiding cerebral reference regions: A systematic review},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {3},
pages = {e0298642},
doi = {10.1371/journal.pone.0298642}
}
EUVIMED