Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 14.05.2024. Verfasst von Giovanny Marquez und 11 weiteren Autor:innen. Beteiligte Einrichtung: Applied Mathematics, Baskin School of Engineering, University of California, Santa Cruz, CA, United States of America. Hauptthemen laut MEDLINE: Precision Medicine. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Defense Advanced Research Projects Agency.
Abstract (Originalsprache)
Precision medicine endeavors to personalize treatments, considering individual variations in patient responses based on factors like genetic mutations, age, and diet. Integrating this approach dynamically, bioelectronics equipped with real-time sensing and intelligent actuation present a promising avenue. Devices such as ion pumps hold potential for precise therapeutic drug delivery, a pivotal aspect of effective precision medicine. However, implementing bioelectronic devices in precision medicine encounters formidable challenges. Variability in device performance due to fabrication inconsistencies and operational limitations, including voltage saturation, presents significant hurdles. To address this, closed-loop control with adaptive capabilities and explicit handling of saturation becomes imperative. Our research introduces an enhanced sliding mode controller capable of managing saturation, adept at satisfactory control actions amidst model uncertainties. To evaluate the controller’s effectiveness, we conducted in silico experiments using an extended mathematical model of the proton pump. Subsequently, we compared the performance of our developed controller with classical Proportional Integral Derivative (PID) and machine learning (ML)–based controllers. Furthermore, in vitro experiments assessed the controller’s efficacy using various reference signals for controlled Fluoxetine delivery. These experiments showcased consistent performance across diverse input signals, maintaining the current value near the reference with a relative error of less than 7% in all trials. Our findings underscore the potential of the developed controller to address challenges in bioelectronic device implementation, offering reliable precision in drug delivery strategies within the realm of precision medicine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Applied Mathematics, Baskin School of Engineering, University of California, Santa Cruz, CA, United States of America.
- Electrical and Computer Engineering, Baskin School of Engineering, University of California, Santa Cruz, CA, United States of America.
- Department of Earth and Space Sciences, Columbus State University, Columbus, GA, United States of America.
ORCID-Profile: Prabhat Baniya, Maryam Tebyani, Mohammad Jafari, Marcella Gomez
Förderung
- Defense Advanced Research Projects Agency
Zitieren
APA
Marquez, G., Dechiraju, H., Baniya, P., Li, H., Tebyani, M., Pansodtee, P., Jafari, M., Barbee, A., Orozco, J., Teodorescu, M., Rolandi, M., & Gomez, M. (2024). Delivering biochemicals with precision using bioelectronic devices enhanced with feedback control. PLOS ONE, 19(5), e0298286. https://doi.org/10.1371/journal.pone.0298286
Vancouver
Marquez G, Dechiraju H, Baniya P, Li H, Tebyani M, Pansodtee P, et al. Delivering biochemicals with precision using bioelectronic devices enhanced with feedback control. PLOS ONE. 2024;19(5):e0298286. doi:10.1371/journal.pone.0298286
BibTeX
@article{Marquez2024,
author = {Marquez, Giovanny and Dechiraju, Harika and Baniya, Prabhat and Li, Houpu and Tebyani, Maryam and Pansodtee, Pattawong and Jafari, Mohammad and Barbee, Alexie and Orozco, Jonathan and Teodorescu, Mircea and Rolandi, Marco and Gomez, Marcella},
title = {Delivering biochemicals with precision using bioelectronic devices enhanced with feedback control},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {5},
pages = {e0298286},
doi = {10.1371/journal.pone.0298286}
}
EUVIMED