Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU
PLOS ONE · 15.02.2024 · 19 (2) · e0297899
DOI: 10.1371/journal.pone.0297899 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 15.02.2024. Verfasst von Bradley M Cornish und 8 weiteren Autor:innen. Beteiligte Einrichtung: Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland, Austr…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stryker.
Abstract (Originalsprache)
Knee function is rarely measured objectively during functional tasks following total knee arthroplasty. Inertial measurement units (IMU) can measure knee kinematics and range of motion (ROM) during dynamic activities and offer an easy-to-use system for knee function assessment post total knee arthroplasty. However, IMU must be validated against gold standard three-dimensional optical motion capture systems (OMC) across a range of tasks if they are to see widespread uptake. We computed knee rotations and ROM from commercial IMU sensor measurements during walking, squatting, sit-to-stand, stair ascent, and stair descent in 21 patients one-year post total knee arthroplasty using two methods: direct computation using segment orientations (r_IMU), and an IMU-driven iCloud-based interactive lower limb model (m_IMU). This cross-sectional study compared computed knee angles and ROM to a gold-standard OMC and inverse kinematics method using Pearson’s correlation coefficient (R) and root-mean-square-differences (RMSD). The r_IMU and m_IMU methods estimated sagittal plane knee angles with excellent correlation (>0.95) compared to OMC for walking, squatting, sit-to-stand, and stair-ascent, and very good correlation (>0.90) for stair descent. For squatting, sit-to-stand, and walking, the mean RMSD for r_IMU and m_IMU compared to OMC were
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland, Australia.
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Queensland, Australia.
- Stryker Corporation, Kalamazoo, Michigan, Unites States of America.
- Coast Orthopaedics and Sports Medicine, Gold Coast, Queensland, Australia.
ORCID-Profile: Bradley M Cornish, Laura E Diamond
Förderung
- Stryker
Zitieren
APA
Cornish, B. M., Diamond, L. E., Saxby, D. J., Lloyd, D. G., Shi, B., Lyon, J., Abbruzzese, K., Gallie, P., & Maharaj, J. (2024). Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU. PLOS ONE, 19(2), e0297899. https://doi.org/10.1371/journal.pone.0297899
Vancouver
Cornish BM, Diamond LE, Saxby DJ, Lloyd DG, Shi B, Lyon J, et al. Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU. PLOS ONE. 2024;19(2):e0297899. doi:10.1371/journal.pone.0297899
BibTeX
@article{Cornish2024,
author = {Cornish, Bradley M and Diamond, Laura E and Saxby, David John and Lloyd, David G and Shi, Beichen and Lyon, Jenna and Abbruzzese, Kevin and Gallie, Price and Maharaj, Jayishni},
title = {Sagittal plane knee kinematics can be measured during activities of daily living following total knee arthroplasty with two IMU},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {2},
pages = {e0297899},
doi = {10.1371/journal.pone.0297899}
}
EUVIMED