EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Repeatability of biometric measures from the IOLMaster 700 in a cataractous population

Achim Langenbucher iD, Nóra Szentmáry, Alan Cayless iD, Peter Hoffmann, Jascha Wendelstein iD, David Cooke

PLOS ONE · 08.02.2024 · 19 (2) · e0297869

DOI: 10.1371/journal.pone.0297869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 08.02.2024. Verfasst von Achim Langenbucher und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany. Hauptthemen laut MEDLINE: Lenses, Intraocular, Cataract. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to investigate the repeatability of biometric measures and also to assess the interactions between the uncertainties in these measures for use in an error propagation model, using data from a large patient cohort.

Methods

In this cross-sectional non-randomised study we evaluated a dataset containing 3379 IOLMaster 700 biometric measurements taken prior to cataract surgery. Only complete scans with at least 3 successful measurements for each eye performed on the same day were considered. The mean (Mean) and standard deviations (SD) for each sequence of measurements were derived and analysed. Correlations between the uncertainties were assessed using Spearman rank correlations.

Results

In the dataset with 677 eyes matching the inclusion criteria, the within subject standard deviation and repeatability for all parameters match previously published data. The SD of the axial length (AL) increased with the Mean AL, but there was no noticeable dependency of the SD of any of the other parameters on their corresponding Mean value. The SDs of the parameters are not independent of one another, and in particular we observe correlations between those for AL, anterior chamber depth, aqueous depth, lens thickness and corneal thickness.

Conclusions

The SD change over Mean for AL measurement and the correlations between the uncertainties of several biometric parameters mean that a simple Gaussian error propagation model cannot be used to derive the effect of biometric uncertainties on the predicted intraocular lens power and refraction after cataract surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularCataractHumansCross-Sectional StudiesAxial Length, EyeProspective StudiesBiometryAnterior Chamber

Autor:innen und Institutionen

  • Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany.
  • Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany.
  • Department of Ophthalmology, Semmelweis-University, Budapest, Hungary.
  • School of Physical Sciences, The Open University, Milton Keynes, United Kingdom.
  • Augen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.
  • Department of Ophthalmology, Johannes Kepler University Linz, Linz, Austria.

ORCID-Profile: Achim Langenbucher, Alan Cayless, Jascha Wendelstein

Zitieren

APA

Langenbucher, A., Szentmáry, N., Cayless, A., Hoffmann, P., Wendelstein, J., & Cooke, D. (2024). Repeatability of biometric measures from the IOLMaster 700 in a cataractous population. PLOS ONE, 19(2), e0297869. https://doi.org/10.1371/journal.pone.0297869

Vancouver

Langenbucher A, Szentmáry N, Cayless A, Hoffmann P, Wendelstein J, Cooke D. Repeatability of biometric measures from the IOLMaster 700 in a cataractous population. PLOS ONE. 2024;19(2):e0297869. doi:10.1371/journal.pone.0297869

BibTeX
@article{Langenbucher2024,
  author = {Langenbucher, Achim and Szentmáry, Nóra and Cayless, Alan and Hoffmann, Peter and Wendelstein, Jascha and Cooke, David},
  title = {Repeatability of biometric measures from the IOLMaster 700 in a cataractous population},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {2},
  pages = {e0297869},
  doi = {10.1371/journal.pone.0297869}
}