Ergonomic benefit using heads-up display compared to conventional surgical microscope in Japanese ophthalmologists
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0297461 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Motohiro Kamei und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Aichi Medical University, Nagakute, Aichi, Japan. Hauptthemen laut MEDLINE: Ergonomics, Ophthalmologists. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alcon Japan Ltd..
Abstract (Originalsprache)
Purpose
Occupational musculoskeletal disorders are prevalent in ophthalmic surgeons and can impact surgeons’ well-being and productivity. Heads-up displays may reduce ergonomic stress compared to conventional microscopes. This cross-sectional, non-interventional study compared ergonomic experience between heads-up display and conventional ocular microscopes.
Methods
The study protocol was approved by the independent ethics committee and nonprofit organization MINS Institutional Review Board. An online questionnaire was distributed to a sample of ophthalmic surgeons in Japan with experience operating with heads-up display. The questionnaire captured surgeon-specific variables, the standardized Nordic Musculoskeletal Questionnaire, and custom questions to compare heads-up display and conventional microscope and understand long-term impacts of musculoskeletal disorders.
Results
Analysis was conducted on responses from 67 surgeons with a mean 25 years of practice and 2.7 years using heads-up display. Many surgeons agreed or strongly agreed that heads-up display reduced the severity (40%) and frequency (40%) of pain and discomfort, improved posture (61%), and improved overall comfort (61%). Of respondents who experienced asthenopia ( n = 59) or pain/discomfort during operation ( n = 61), 54% reported improvement in asthenopia and 72% reported feeling less pain/discomfort since using heads-up display. Overall, 69% reported preference for heads-up display.
Conclusion
This study provides novel data on musculoskeletal disorders and the long-term impacts of ergonomic strain reported by ophthalmologists building on existing literature demonstrating ergonomic and other advantages of heads-up display. Future studies with objective ergonomic assessment are warranted to validate these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Aichi Medical University, Nagakute, Aichi, Japan.
- Zengyo Suzuki Eye Clinic, Fujisawa-shi, Kanagawa, Japan.
- Alcon Japan Ltd., Tokyo, Japan.
- Eversana Life Science Services, Burlington, Ontario, Canada.
- Alcon Vision LLC, Fort Worth, Texas, United States of America.
- Department of Ophthalmology, Kobe University, Kobe City, Hyogo, Japan.
ORCID-Profile: Margaret H Ainslie-Garcia, Makoto Nakamura
Förderung
- Alcon Japan Ltd.
Zitieren
APA
Kamei, M., Suzuki, H., Terayama, H., Ghafouri, R., Ainslie-Garcia, M. H., Ferko, N. C., Cheng, H., O'Boyle, D., & Nakamura, M. (2024). Ergonomic benefit using heads-up display compared to conventional surgical microscope in Japanese ophthalmologists. PLOS ONE. https://doi.org/10.1371/journal.pone.0297461
Vancouver
Kamei M, Suzuki H, Terayama H, Ghafouri R, Ainslie-Garcia MH, Ferko NC, et al. Ergonomic benefit using heads-up display compared to conventional surgical microscope in Japanese ophthalmologists. PLOS ONE. 2024. doi:10.1371/journal.pone.0297461
BibTeX
@article{Kamei2024,
author = {Kamei, Motohiro and Suzuki, Hisaharu and Terayama, Hideyuki and Ghafouri, Rana and Ainslie-Garcia, Margaret H and Ferko, Nicole C and Cheng, Hang and O'Boyle, Derek and Nakamura, Makoto},
title = {Ergonomic benefit using heads-up display compared to conventional surgical microscope in Japanese ophthalmologists},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0297461}
}
EUVIMED