Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0296958 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Ivan Jambor und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Turku, Turku, Finland. Hauptthemen laut MEDLINE: Brain Neoplasms, Glioma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In pre-clinical models of brain gliomas, Relaxation Along a Fictitious Field in second rotating frame (T RAFF2 ), continues wave T 1rho (T 1ρcw ), adiabatic T 1rho (T 1ρadiab ), and adiabatic T 2rho (T 2ρadiab ) relaxation time mappings have demonstrated potential to non-invasively characterize brain gliomas. Our aim was to evaluate the feasibility and potential of 4 different spin lock methods at 3T to characterize primary brain glioma. 22 patients (26–72 years) with suspected primary glioma. T 1ρcw was performed using pulse peak amplitude of 500Hz and pulse train durations of 40 and 80 ms while the corresponding values for T 1ρadiab , T 2ρadiab , T RAFF2 were 500/500/500Hz and 48 and 96, 64 and 112, 45 and 90 ms, respectively. The parametric maps were calculated using a monoexponential model. Molecular profiles were evaluated from tissue specimens obtained during the resection. The lesion regions-of-interest were segmented from high intensity FLAIR using automatic segmentation with manual refinement. Statistical descriptors from the voxel intensity values inside each lesion and radiomic features (Pyrad MRC package) were calculated. From extracted radiomics, mRMRe R package version 2.1.0 was used to select 3 features in each modality for statistical comparisons. Of the 22 patients, 10 were found to have IDH-mutant gliomas and of those 5 patients had 1p/19q codeletion group comparisons. Following correction for effects of age and gender, at least one statistical descriptor was able to differentiate between IDH and 1p/19q codeletion status for all the parametric maps. In the radiomic analysis, corner-edge detector features with Harris-Stephens filtered signal showed significant group differences in IDH and 1p/19q codeletion groups. Spin lock imaging at 3T of human glioma was feasible and various qualitative parameters derived from the parametric maps were found to have potential to differentiate IDH and 1p19q codeletion status. Future larger prospective clinical trials are warranted to evaluate these methods further.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Turku, Turku, Finland.
- Enterprise Service Group-Radiology, Mass General Brigham, Boston, MA, United States of America.
- Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku, Finland.
- Tyks Laboratories, Pathology, Turku University Hospital and Institute of Biomedicine, University of Turku Turku, Finland.
- Division of Clinical Neurosciences, Department of Neurosurgery, Turku University Hospital and University of Turku, Turku, Finland.
- Department of Radiology, University of Oulu, Oulu, Finland.
ORCID-Profile: Ivan Jambor, Heikki Minn
Zitieren
APA
Jambor, I., Steiner, A., Pesola, M., Gardberg, M., Frantzén, J., Jokinen, P., Liimatainen, T., Minn, H., Aronen, H., & Merisaari, H. (2024). Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study. PLOS ONE. https://doi.org/10.1371/journal.pone.0296958
Vancouver
Jambor I, Steiner A, Pesola M, Gardberg M, Frantzén J, Jokinen P, et al. Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study. PLOS ONE. 2024. doi:10.1371/journal.pone.0296958
BibTeX
@article{Jambor2024,
author = {Jambor, Ivan and Steiner, Aida and Pesola, Marko and Gardberg, Maria and Frantzén, Janek and Jokinen, Pekka and Liimatainen, Timo and Minn, Heikki and Aronen, Hannu and Merisaari, Harri},
title = {Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0296958}
}