Monitoring mobility in older adults using a Global Positioning System (GPS) smartwatch and accelerometer: A validation study

Marla Beauchamp iD, Renata Kirkwood, Cody Cooper, Matthew Brown iD, K Bruce Newbold iD, Darren Scott iD, MacM3 team

PLOS ONE · 21.12.2023 · 18 (12) · e0296159

DOI: 10.1371/journal.pone.0296159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 21.12.2023. Verfasst von Marla Beauchamp und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Rehabilitation Science, McMaster University, Hamilton, Ontario, Canada. Hauptthemen laut MEDLINE: Geographic Information Systems, Algorithms. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AGE-WELL, McMaster Institute for Research on Aging, McMaster University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is growing interest in identifying valid and reliable methods for detecting early mobility limitations in aging populations. A multi-sensor approach that combines accelerometry with Global Positioning System (GPS) devices could provide valuable insights into late-life mobility decline; however, this innovative approach requires more investigation. We conducted a series of two experiments with 25 older participants (66.2±8.5 years) to determine the validity of a GPS enabled smartwatch (TicWatch S2 and Pro 3 Ultra GPS) and separate accelerometer (ActiGraph wGT3X-BT) to collect movement, navigation and body posture data relevant to mobility. In experiment 1, participants wore the TicWatchS2 and ActiGraph simultaneously on the wrist for 3 days. In experiment 2, participants wore the TicWatch Pro 2 Ultra GPS on the wrist and ActiGraph on the thigh for 3 days. In both experiments participants also carried a Qstarz data logger for trips outside the home. The TicWatch Pro 3 Ultra GPS performed better than the S2 model and was similar to the Qstarz in all tested trip-related measures, and it was able to estimate both passive and active trip modes. Both models showed similar results to the gold standard Qstarz in life-space-related measures. The TicWatch S2 demonstrated good to excellent overall agreement with the ActiGraph algorithms for the time spent in sedentary and non-sedentary activities, with 84% and 87% agreement rates, respectively. Under controlled conditions, the TicWatch Pro 3 Ultra GPS consistently measured step count in line with the participants’ self-reported data, with a bias of 0.4 steps. The thigh-worn ActiGraph algorithm accurately classified sitting and lying postures (97%) and standing postures (90%). Our multi-sensor approach to monitoring mobility has the potential to capture both accelerometer-derived movement data and trip/life-space data only available through GPS. In this study, we found that the TicWatch models were valid devices for capturing GPS and raw accelerometer data, making them useful tools for assessing real-life mobility in older adults.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Geographic Information SystemsAlgorithmsHumansAgedSelf ReportWristAccelerometry

Autor:innen und Institutionen

  • School of Rehabilitation Science, McMaster University, Hamilton, Ontario, Canada.
  • School of Earth, Environment & Society, McMaster University, Hamilton, Ontario, Canada.

ORCID-Profile: Marla Beauchamp, Matthew Brown, K Bruce Newbold, Darren Scott

Förderung

  • AGE-WELL
  • McMaster Institute for Research on Aging, McMaster University

Zitieren

APA

Beauchamp, M., Kirkwood, R., Cooper, C., Brown, M., Newbold, K. B., Scott, D., & MacM3 team (2023). Monitoring mobility in older adults using a Global Positioning System (GPS) smartwatch and accelerometer: A validation study. PLOS ONE, 18(12), e0296159. https://doi.org/10.1371/journal.pone.0296159

Vancouver

Beauchamp M, Kirkwood R, Cooper C, Brown M, Newbold KB, Scott D, et al. Monitoring mobility in older adults using a Global Positioning System (GPS) smartwatch and accelerometer: A validation study. PLOS ONE. 2023;18(12):e0296159. doi:10.1371/journal.pone.0296159

BibTeX
@article{Beauchamp2023,
  author = {Beauchamp, Marla and Kirkwood, Renata and Cooper, Cody and Brown, Matthew and Newbold, K Bruce and Scott, Darren and MacM3 team, MacM3 team},
  title = {Monitoring mobility in older adults using a Global Positioning System (GPS) smartwatch and accelerometer: A validation study},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {12},
  pages = {e0296159},
  doi = {10.1371/journal.pone.0296159}
}
Kostenlos starten →