EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of Skyline software for detecting prohibited substances in doping control analysis

Hyeon-Jeong Lee, Mijin Jeon, Yoondam Seo, Inseon Kang, Wooyeon Jeong, Junghyun Son, Eugene C Yi, Hophil Min iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0295065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Hyeon-Jeong Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Doping Control Center, Korea Institute of Science and Technology, Seongbuk-gu, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Doping in Sports. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Institute of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the number of prohibited drugs has been progressively increasing and analytical methods for detecting such substances are renewed continuously for doping control, the need for more sensitive and accurate doping analysis has increased. To address the urgent need for high throughput and accurate analysis, liquid chromatography with tandem mass spectrometry is actively utilized in case of most of the newly designated prohibited substances. However, because all mass spectrometer vendors provide data processing software that is incapable of handling other instrumental data, it is difficult to cover all doping analysis procedures, from method development to result reporting, on one platform. Skyline is an open-source and vendor-neutral software program invented for the method development and data processing of targeted proteomics. Recently, the utilization of Skyline has been expanding for the quantitative analysis of small molecules and lipids. Herein, we demonstrated Skyline as a simple platform for unifying overall doping control, including the optimization of analytical methods, monitoring of data quality, discovery of suspected doping samples, and validation of analytical methods for detecting newly prohibited substances. For method optimization, we selected the optimal collision energies for 339 prohibited substances. Notably, 195 substances exhibited a signal intensity increase of >110% compared with the signal intensity of the original collision energy. All data related to method validation and quantitative analysis were efficiently visualized, extracted, or calculated using Skyline. Moreover, a comparison of the time consumed and the number of suspicious samples screened in the initial test procedure highlighted the advantages of using Skyline over the commercially available software TraceFinder in doping control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryDoping in SportsChromatography, LiquidSoftwareProteomics

Autor:innen und Institutionen

  • Doping Control Center, Korea Institute of Science and Technology, Seongbuk-gu, Seoul, Republic of Korea.
  • Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Yeongeon-dong, Jongno-gu, Seoul, Republic of Korea.

ORCID-Profile: Hophil Min

Förderung

  • National Research Foundation of Korea
  • Korea Institute of Science and Technology

Zitieren

APA

Lee, H. J., Jeon, M., Seo, Y., Kang, I., Jeong, W., Son, J., Yi, E. C., & Min, H. (2023). Application of Skyline software for detecting prohibited substances in doping control analysis. PLOS ONE. https://doi.org/10.1371/journal.pone.0295065

Vancouver

Lee HJ, Jeon M, Seo Y, Kang I, Jeong W, Son J, et al. Application of Skyline software for detecting prohibited substances in doping control analysis. PLOS ONE. 2023. doi:10.1371/journal.pone.0295065

BibTeX
@article{Lee2023,
  author = {Lee, Hyeon-Jeong and Jeon, Mijin and Seo, Yoondam and Kang, Inseon and Jeong, Wooyeon and Son, Junghyun and Yi, Eugene C and Min, Hophil},
  title = {Application of Skyline software for detecting prohibited substances in doping control analysis},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0295065}
}
Kostenlos starten →