A multiplex Taqman PCR assay for MRSA detection from whole blood
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0294782 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Suhanya Duraiswamy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Methicillin-Resistant Staphylococcus aureus, Staphylococcal Infections. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scheme for Transformational and Advanced Research in Sciences, Prime Ministers Reaearch Fellowship, India, Singapore SERC Strategic Funds.
Abstract (Originalsprache)
Methicillin-resistant Staphylococcus aureus ( MRSA ) causes a wide range of hospital and community-acquired infections worldwide. MRSA is associated with worse clinical outcomes that can lead to multiple organ failure, septic shock, and death, making timely diagnosis of MRSA infections very crucial. In the present work, we develop a method that enables the positive enrichment of bacteria from spiked whole blood using protein coated magnetic beads, followed by their lysis, and detection by a real-time multiplex PCR directly. The assay targeted bacterial 16S rRNA, S . aureus ( spa ) and methicillin resistance ( mecA ). In addition, an internal control (lambda phage) was added to determine the assay’s true negative. To validate this assay, staphylococcal and non-staphylococcal bacterial strains were used. The three-markers used in this study were detected as expected by monomicrobial and poly-microbial models of the S . aureus and coagulase-negative staphylococci ( CoNS ). The thermal cycling completed within 30 mins, delivering 100% specificity. The detection LoD of the pre-processing step was ∼ 1 CFU/mL from 2-5mL of whole blood and that of PCR was ∼ 1pg of NA. However, the combined protocol led to a lower detection limit of 100–1000 MRSA CFUs/mL. The main issue with the method developed is in the pre-processing of blood which will be the subject of our future study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Telangana, India.
- Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), Singapore, Republic of Singapore.
ORCID-Profile: Suhanya Duraiswamy, Ruige Wu
Förderung
- Scheme for Transformational and Advanced Research in Sciences
- Prime Ministers Reaearch Fellowship, India
- Singapore SERC Strategic Funds
- Industry alignment fund - Industry Collaboration Projects
Zitieren
APA
Duraiswamy, S., Agarwalla, S., Lok, K. S., Tse, Y. Y., Wu, R., & Wang, Z. (2023). A multiplex Taqman PCR assay for MRSA detection from whole blood. PLOS ONE. https://doi.org/10.1371/journal.pone.0294782
Vancouver
Duraiswamy S, Agarwalla S, Lok KS, Tse YY, Wu R, Wang Z. A multiplex Taqman PCR assay for MRSA detection from whole blood. PLOS ONE. 2023. doi:10.1371/journal.pone.0294782
BibTeX
@article{Duraiswamy2023,
author = {Duraiswamy, Suhanya and Agarwalla, Sushama and Lok, Khoi Sheng and Tse, Yee Yung and Wu, Ruige and Wang, Zhiping},
title = {A multiplex Taqman PCR assay for MRSA detection from whole blood},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0294782}
}
EUVIMED