Comparison of stereopsis thresholds measured with conventional methods and a new eye tracking method

Lu Liu, Bo Yu, Lingxian Xu, Shiyi Wang, Lingzhi Zhao, Huang Wu iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0293735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Lu Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, The Second Hospital of Jilin University, Changchun, China. Hauptthemen laut MEDLINE: Eye-Tracking Technology, Vision, Binocular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Jilin Provincial Science & Technology Department, China, the Graduate Innovation Fund of Jilin University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Stereopsis is the ability to perceive depth using the slightly different views from two eyes. This study aims to conduct innovative stereopsis tests using the objective data outputted by eye tracking technology.

Methods

A laptop and an eye tracker were used to establish the test system. Anaglyphic glasses were employed to execute the stereopsis assessment. The test symbol employed was devised to emulate the quantitative measurement component of the Random Dot 3 Stereo Acuity Test. Sub-pixel technology was used to increase the disparity accuracy of test pages. The tested disparities were: 160″, 100″, 63″, 50″, 40″, 32″, 25″, 20″, 16″, and 12.5″. The test was conducted at a distance of 0.65m. Conventional and eye tracking stereopsis assessments were conducted on 120 subjects. Wilcoxon signed-rank test was used to test the difference, while the Bland-Altman method was used to test the consistency between the two methods.

Results

The Wilcoxon signed-rank test showed no significant difference between conventional and eye tracking thresholds of stereopsis ( Z = −1.497, P = 0.134). There was a high level of agreement between the two methods using Bland- Altman statistical analysis (The 95 per cent limits of agreement were −0.40 to 0.47 log arcsec).

Conclusions

Stereoacuity can be evaluated utilizing an innovative stereopsis measurement system grounded in eye tracking technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eye-Tracking TechnologyVision, BinocularHumansVision TestsDepth PerceptionVisual Acuity

Autor:innen und Institutionen

  • Department of Optometry, The Second Hospital of Jilin University, Changchun, China.

ORCID-Profile: Huang Wu

Förderung

  • the Jilin Provincial Science & Technology Department, China
  • the Graduate Innovation Fund of Jilin University

Zitieren

APA

Liu, L., Yu, B., Xu, L., Wang, S., Zhao, L., & Wu, H. (2023). Comparison of stereopsis thresholds measured with conventional methods and a new eye tracking method. PLOS ONE. https://doi.org/10.1371/journal.pone.0293735

Vancouver

Liu L, Yu B, Xu L, Wang S, Zhao L, Wu H. Comparison of stereopsis thresholds measured with conventional methods and a new eye tracking method. PLOS ONE. 2023. doi:10.1371/journal.pone.0293735

BibTeX
@article{Liu2023,
  author = {Liu, Lu and Yu, Bo and Xu, Lingxian and Wang, Shiyi and Zhao, Lingzhi and Wu, Huang},
  title = {Comparison of stereopsis thresholds measured with conventional methods and a new eye tracking method},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0293735}
}
Kostenlos starten →