EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD)

Martin S Zand iD, Samantha Spallina iD, Alexis Ross, Karen Zandi, Anne Pawlowski, Christopher L Seplaki, Jonathan Herington iD, Anthony M Corbett iD, Kimberly Kaukeinen, Jeanne Holden-Wiltse iD, Edward G Freedman, Lisette Alcantara iD und 6 weitere

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0291840 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Martin S Zand und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Nephrology, University of Rochester, Rochester, NY, United States of America. Hauptthemen laut MEDLINE: COVID-19. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS, NCATS NIH HHS, Eunice Kennedy Shriver National Institute of Child Health and Human Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study examined the correlation of classroom ventilation (air exchanges per hour (ACH)) and exposure to CO 2 ≥1,000 ppm with the incidence of SARS-CoV-2 over a 20-month period in a specialized school for students with intellectual and developmental disabilities (IDD). These students were at a higher risk of respiratory infection from SARS-CoV-2 due to challenges in tolerating mitigation measures (e.g. masking). One in-school measure proposed to help mitigate the risk of SARS-CoV-2 infection in schools is increased ventilation.

Methods

We established a community-engaged research partnership between the University of Rochester and the Mary Cariola Center school for students with IDD. Ambient CO 2 levels were measured in 100 school rooms, and air changes per hour (ACH) were calculated. The number of SARS-CoV-2 cases for each room was collected over 20 months.

Results

97% of rooms had an estimated ACH ≤4.0, with 7% having CO 2 levels ≥2,000 ppm for up to 3 hours per school day. A statistically significant correlation was found between the time that a room had CO 2 levels ≥1,000 ppm and SARS-CoV-2 PCR tests normalized to room occupancy, accounting for 43% of the variance. No statistically significant correlation was found for room ACH and per-room SARS-CoV-2 cases. Rooms with ventilation systems using MERV-13 filters had lower SARS-CoV-2-positive PCR counts. These findings led to ongoing efforts to upgrade the ventilation systems in this community-engaged research project.

Conclusions

There was a statistically significant correlation between the total time of room CO 2 concentrations ≥1,000 and SARS-CoV-2 cases in an IDD school. Merv-13 filters appear to decrease the incidence of SARS-CoV-2 infection. This research partnership identified areas for improving in-school ventilation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19ChildHumansSARS-CoV-2Carbon DioxideDevelopmental DisabilitiesSchoolsStudentsVentilation

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Department of Medicine, Division of Nephrology, University of Rochester, Rochester, NY, United States of America.
  • Clinical and Translational Science Institute, University of Rochester, Rochester, NY, United States of America.
  • Department of Public Health Sciences, University of Rochester, Rochester, NY, United States of America.
  • The Frederick J. and Marion A. Schindler Cognitive Neurophysiology Laboratory, The Ernest J. Del Monte Institute for Neuroscience, Department of Neuroscience, University of Rochester School of Medicine and Dentistry, Ro…
  • The Mary Cariola Center, Rochester, NY, United States of America.
  • Department of Psychiatry, University of Rochester, Rochester, NY, United States of America.

ORCID-Profile: Martin S Zand, Samantha Spallina, Jonathan Herington, Anthony M Corbett, Jeanne Holden-Wiltse, Lisette Alcantara, Andrew Cameron, John J Foxe

Förderung

  • NICHD NIH HHS
  • NCATS NIH HHS
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development
  • National Center for Advancing Translational Sciences

Zitieren

APA

Zand, M. S., Spallina, S., Ross, A., Zandi, K., Pawlowski, A., Seplaki, C. L., Herington, J., Corbett, A. M., Kaukeinen, K., Holden-Wiltse, J., Freedman, E. G., Alcantara, L., Li, D., Cameron, A., Beaumont, N., Dozier, A., Dewhurst, S., & Foxe, J. J. (2024). Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD). PLOS ONE. https://doi.org/10.1371/journal.pone.0291840

Vancouver

Zand MS, Spallina S, Ross A, Zandi K, Pawlowski A, Seplaki CL, et al. Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD). PLOS ONE. 2024. doi:10.1371/journal.pone.0291840

BibTeX
@article{Zand2024,
  author = {Zand, Martin S and Spallina, Samantha and Ross, Alexis and Zandi, Karen and Pawlowski, Anne and Seplaki, Christopher L and Herington, Jonathan and Corbett, Anthony M and Kaukeinen, Kimberly and Holden-Wiltse, Jeanne and Freedman, Edward G and Alcantara, Lisette and Li, Dongmei and Cameron, Andrew and Beaumont, Nicole and Dozier, Ann and Dewhurst, Stephen and Foxe, John J},
  title = {Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD)},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0291840}
}
Kostenlos starten →