EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy

Chun-Hsu Yao, Eng-Yen Huang, Kuo-Jung Juan, Pei-Jiuan Juang, Ying-Hsuan Juan, Yuan-Jen Chang iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0291507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Chun-Hsu Yao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Master Program for Biomedical Engineering / School of Chinese Medicine, China Medical University, Taichung City, Taiwan, R.O.C. Hauptthemen laut MEDLINE: Proton Therapy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology, Taiwan, Clinical Trial Center, China Medical University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to investigate the feasibility of applying 3D gel dosimeters for proton therapy. Two different formulations (5-5-3-5, 5-3-3-10) for the N-Isopropyl Acrylamide (NIPAM) polymer gel were used to find the best composition for the application of NIPAM polymer gels for proton therapy. The reaction of the gel under different physical conditions, including dependence on energy and dependence on the dose rate of the NIPAM gel under proton irradiation, was also explored. A NIPAM gel dosimeter was used to record the 3D dose distribution, and a self-developed parallel beam optical computed tomography scanner was used to obtain non-irradiated and post-irradiated gel phantom images. The NIPAM gel was filled into a cylindrical acrylic phantom. The results showed that the optical density of the irradiated NIPAM dosimeter was linear in the dose range of 0 to 6 Gy, and the linearity of the two NIPAM gel formulations at the depth of the dose point (2 cm) was 0.98 to 0.89. The dose depth curves showed different patterns with different gel sensitivities. This study demonstrated that the NIPAM gel dosimeter with the 5-3-3-10 formulation is suitable for verifying the dosimetry dose of proton beams.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyRadiation DosimetersFeasibility StudiesProtonsAcrylamidesGelsPolymers

Substanzen

ProtonsN-isopropylacrylamideAcrylamidesGelsPolymers

Autor:innen und Institutionen

  • Department of Master Program for Biomedical Engineering / School of Chinese Medicine, China Medical University, Taichung City, Taiwan, R.O.C.
  • Biomaterials Translational Research Center, China Medical University Hospital, Taichung City, Taiwan, R.O.C.
  • Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan, R.O.C.
  • School of Chinese Medicine, China Medical University, Taichung City, Taiwan, R.O.C.
  • Department of Biomedical Informatics, Asia University, Taichung City, Taiwan, R.O.C.
  • Department of Radiation Oncology, Chang Gung Memorial Hospital Kaohsiung Branch, Niao-Sung District, Kaohsiung, Taiwan, R.O.C.

ORCID-Profile: Yuan-Jen Chang

Förderung

  • Ministry of Science and Technology, Taiwan
  • Clinical Trial Center, China Medical University Hospital

Zitieren

APA

Yao, C. H., Huang, E. Y., Juan, K. J., Juang, P. J., Juan, Y. H., & Chang, Y. J. (2023). Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy. PLOS ONE. https://doi.org/10.1371/journal.pone.0291507

Vancouver

Yao CH, Huang EY, Juan KJ, Juang PJ, Juan YH, Chang YJ. Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy. PLOS ONE. 2023. doi:10.1371/journal.pone.0291507

BibTeX
@article{Yao2023,
  author = {Yao, Chun-Hsu and Huang, Eng-Yen and Juan, Kuo-Jung and Juang, Pei-Jiuan and Juan, Ying-Hsuan and Chang, Yuan-Jen},
  title = {Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0291507}
}
Kostenlos starten →