Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0289052 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift PLOS ONE, 2023. Verfasst von Carli Lessof und 17 weiteren Autor:innen. Beteiligte Einrichtung: National Centre for Research Methods, University of Southampton, Southampton, United Kingdom. Hauptthemen laut MEDLINE: Blood Pressure Determination, Hand Strength. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, Economic and Social Research Council, National Institute for Health Research (NIHR) Biomedical Research Centre.
Abstract (Originalsprache)
Background
Blood pressure, grip strength and lung function are frequently assessed in longitudinal population studies, but the measurement devices used differ between studies and within studies over time. We aimed to compare measurements ascertained from different commonly used devices.
Methods
We used a randomised cross-over study. Participants were 118 men and women aged 45–74 years whose blood pressure, grip strength and lung function were assessed using two sphygmomanometers (Omron 705-CP and Omron HEM-907), four handheld dynamometers (Jamar Hydraulic, Jamar Plus+ Digital, Nottingham Electronic and Smedley) and two spirometers (Micro Medical Plus turbine and ndd Easy on-PC ultrasonic flow-sensor) with multiple measurements taken on each device. Mean differences between pairs of devices were estimated along with limits of agreement from Bland-Altman plots. Sensitivity analyses were carried out using alternative exclusion criteria and summary measures, and using multilevel models to estimate mean differences.
Results
The mean difference between sphygmomanometers was 3.9mmHg for systolic blood pressure (95% Confidence Interval (CI):2.5,5.2) and 1.4mmHg for diastolic blood pressure (95% CI:0.3,2.4), with the Omron HEM-907 measuring higher. For maximum grip strength, the mean difference when either one of the electronic dynamometers was compared with either the hydraulic or spring-gauge device was 4-5kg, with the electronic devices measuring higher. The differences were small when comparing the two electronic devices (difference = 0.3kg, 95% CI:-0.9,1.4), and when comparing the hydraulic and spring-gauge devices (difference = 0.2kg, 95% CI:-0.8,1.3). In all cases limits of agreement were wide. The mean difference in FEV 1 between spirometers was close to zero (95% CI:-0.03,0.03), limits of agreement were reasonably narrow, but a difference of 0.47l was observed for FVC (95% CI:0.53,0.42), with the ndd Easy on-PC measuring higher.
Conclusion
Our study highlights potentially important differences in measurement of key functions when different devices are used. These differences need to be considered when interpreting results from modelling intra-individual changes in function and when carrying out cross-study comparisons, and sensitivity analyses using correction factors may be helpful.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- National Centre for Research Methods, University of Southampton, Southampton, United Kingdom.
- Faculty of Medical Sciences, Translational and Clinical Research Institute, AGE Research Group, Newcastle University, Newcastle upon Tyne, United Kingdom.
- NIHR Newcastle Biomedical Research Centre, Newcastle University and Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, United Kingdom.
- MRC Unit for Lifelong Health and Ageing at UCL, London, United Kingdom.
- Department of Biostatistics and Health Informatics of the Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, United Kingdom.
- NIHR Biomedical Research Centre at South London and Maudsley, NHS Foundation Trust and King's College London, London, United Kingdom.
ORCID-Profile: Rachel Cooper, Andrew Wong, Rebecca Hardy
Förderung
- Medical Research Council
- Economic and Social Research Council
- National Institute for Health Research (NIHR) Biomedical Research Centre
Zitieren
APA
Lessof, C., Cooper, R., Wong, A., Bendayan, R., Caleyachetty, R., Cheshire, H., Cosco, T., Elhakeem, A., Hansell, A. L., Kaushal, A., Kuh, D., Martin, D., Minelli, C., Muthuri, S., Popham, M., Shaheen, S. O., Sturgis, P., & Hardy, R. (2023). Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study. PLOS ONE. https://doi.org/10.1371/journal.pone.0289052
Vancouver
Lessof C, Cooper R, Wong A, Bendayan R, Caleyachetty R, Cheshire H, et al. Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study. PLOS ONE. 2023. doi:10.1371/journal.pone.0289052
BibTeX
@article{Lessof2023,
author = {Lessof, Carli and Cooper, Rachel and Wong, Andrew and Bendayan, Rebecca and Caleyachetty, Rishi and Cheshire, Hayley and Cosco, Theodore and Elhakeem, Ahmed and Hansell, Anna L and Kaushal, Aradhna and Kuh, Diana and Martin, David and Minelli, Cosetta and Muthuri, Stella and Popham, Maria and Shaheen, Seif O and Sturgis, Patrick and Hardy, Rebecca},
title = {Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0289052}
}
EUVIMED