A sensitive tissue factor activity assay determined by an optimized thrombin generation method
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0288918 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Søren Risom Kristensen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark. Hauptthemen laut MEDLINE: Thrombin, Extracellular Vesicles. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Tissue factor (TF) is the principal activator of the coagulation system, but an increased concentration in the blood in cancer and inflammatory diseases has been suggested to play a role increasing the risk of venous thromboembolism. However, measurement of the TF concentration is difficult, and quantitation of activity is the most valid estimation. The objective of this study was to establish a sensitive method to measure TF activity based on thrombin generation.
Methods
The assay is based on thrombin generation (TG) measured on the Calibrated Automated Thrombogram (CAT). Various low concentrations of TF were prepared from reagents containing 1 pM TF and 4 μM phospholipid (PPL), and no TF and 4 μM PPL, and a calibration curve was produced from Lagtime vs TF concentration. TF in blood samples was measured after isolation and resuspension of extracellular vesicles (EVs) in a standard plasma from which EVs had been removed. The same standard plasma was used for the calibrators.
Results
Contact activation of the coagulation system was avoided using CTI plasma samples in Monovette tubes. EVs contain procoagulant phospholipids but addition of PPL only reduced lagtime slightly at very low concentrations of TF resulting in overestimation to a lesser extent at 10 fM but no interference at 30 fM or higher. Addition of EVs to the TG analysis induced a small unspecific TF-independent activity (i.e., an activity not inhibited by antibodies against TF) which also may result in a smaller error in estimation of TF activity at very low levels but the effect was negligible at higher concentrations. It was possible to measure TF activity in healthy controls which was found to be 1–6 fM (EVs were concentrated, i.e. solubilized in a lower volume than the original volume plasma). Coefficient of variation (CV) was below 20% at the low level, and below 10% at a level around 100 fM TF. However, the step with isolation of EVs have a higher inherent CV.
Conclusion
A sensitive and rather precise one-stage TG-based method to measure TF activity has been established.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Clinical Biochemistry, Aalborg University Hospital, Aalborg, Denmark.
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
ORCID-Profile: Søren Risom Kristensen
Zitieren
APA
Kristensen, S. R., & Nybo, J. (2023). A sensitive tissue factor activity assay determined by an optimized thrombin generation method. PLOS ONE. https://doi.org/10.1371/journal.pone.0288918
Vancouver
Kristensen SR, Nybo J. A sensitive tissue factor activity assay determined by an optimized thrombin generation method. PLOS ONE. 2023. doi:10.1371/journal.pone.0288918
BibTeX
@article{Kristensen2023,
author = {Kristensen, Søren Risom and Nybo, Jette},
title = {A sensitive tissue factor activity assay determined by an optimized thrombin generation method},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0288918}
}
EUVIMED