Comparison of new and old BacT/ALERT aerobic bottles for detection of Candida species
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0288674 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Kye Won Choe und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Candidemia, Bacteremia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea (NRF) grant funded by the Korean government.
Abstract (Originalsprache)
Purpose
A new version of aerobic blood culture media has been developed for the BacT/ALERT (bioMérieux) blood culture system. We evaluated the time to detection and yeast cell counts in positive blood cultures for each Candida spp. according to changes in media.
Methods
Isolates from defibrinated horse blood were inoculated into three types of bottles: the old version of aerobic bottle, new version of aerobic bottle, and anaerobic bottle. All bottles were incubated in the BacT/ALERT Virtuo blood culture system. The time to detection was monitored for each bottle, and yeast cell counts were performed immediately after testing positive, determined via the plate count method. Clinical retrospective data of the candidemia samples before and after aerobic bottle change also were analyzed.
Results
The median time to detection was 52.47 hours in the old aerobic bottles versus 19.92 hours in the new aerobic bottles ( P < 0.001) for Candida glabrata , and standard and clinical strains showed similar results. C. albicans (27.6 to 24.95 hours) and C. guilliermondii (28.92 to 26.9 hours) had shorter time to detection. However, C. auris (25.43 to 28.25 hours) had a longer time to detection in the new aerobic bottle. The retrospective clinical analysis showed a significant decrease in time to detection (45.0 to 19.4 hours) for C. glabrata , which is consistent with our simulated study result for C. glabrata . As a result of analysis including all blood specimens, C. tropicalis showed a significant delay in time to detection in new aerobic bottles. In an analysis limited to peripheral blood specimens, the time to detection of C. parapsilosis was longer in new aerobic bottles than in old aerobic bottles.
Conclusion
Most Candida species did not show remarkable TTD differences, but TTD of C. glabrata was markedly reduced in the New FA Plus bottle. The reduction of time to detection enables faster detection and therapeutic approach for C. glabrata infections.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Kye Won Choe, Yong Kwan Lim, Mi-Kyung Lee
Förderung
- National Research Foundation of Korea (NRF) grant funded by the Korean government
Zitieren
APA
Choe, K. W., Lim, Y. K., & Lee, M. K. (2023). Comparison of new and old BacT/ALERT aerobic bottles for detection of Candida species. PLOS ONE. https://doi.org/10.1371/journal.pone.0288674
Vancouver
Choe KW, Lim YK, Lee MK. Comparison of new and old BacT/ALERT aerobic bottles for detection of Candida species. PLOS ONE. 2023. doi:10.1371/journal.pone.0288674
BibTeX
@article{Choe2023,
author = {Choe, Kye Won and Lim, Yong Kwan and Lee, Mi-Kyung},
title = {Comparison of new and old BacT/ALERT aerobic bottles for detection of Candida species},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0288674}
}
EUVIMED