Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot
PLOS ONE · 14.07.2023 · 18 (7) · e0288664
DOI: 10.1371/journal.pone.0288664 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 14.07.2023. Verfasst von L St George und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Applied Sport and Exercise Sciences, University of Central Lancashire, Preston, Lancashire, United Kingdom. Hauptthemen laut MEDLINE: Muscle, Skeletal. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Morris Animal Foundation, British Society of Animal Science.
Abstract (Originalsprache)
The reliability of surface electromyography (sEMG) has not been adequately demonstrated in the equine literature and is an essential consideration as a methodology for application in clinical gait analysis. This observational study investigated within-session, intra-subject (stride-to-stride) and inter-subject reliability, and between-session reliability of normalised sEMG activity profiles, from triceps brachii (triceps), latissimus dorsi (latissimus), longissimus dorsi (longissimus), biceps femoris (biceps), superficial gluteal (gluteal) and semitendinosus muscles in n = 8 clinically non-lame horses during in-hand trot. sEMG sensors were bilaterally located on muscles to collect data during two test sessions (session 1 and 2) with a minimum 24-hour interval. Raw sEMG signals from ten trot strides per horse and session were DC-offset removed, high-pass filtered (40 Hz), full-wave rectified, and low-pass filtered (25 Hz). Signals were normalised to peak amplitude and percent stride before calculating intra- and inter-subject ensemble average sEMG profiles across strides for each muscle and session. sEMG profiles were assessed using waveform similarity statistics: the coefficient of variation (CV) to assess intra- and inter-subject reliability and the adjusted coefficient of multiple correlation (CMC) to evaluate between-session reliability. Across muscles, CV data revealed that intra-horse sEMG profiles within- and between-sessions were comparatively more reliable than inter-horse profiles. Bilateral gluteal, semitendinosus, triceps and longissimus (at T14 and L1) and right biceps showed excellent between-session reliability with group-averaged CMCs > 0.90 (range 0.90–0.97). Bilateral latissimus and left biceps showed good between-session reliability with group-averaged CMCs > 0.75 (range 0.78–0.88). sEMG profiles can reliably describe fundamental muscle activity patterns for selected equine muscles within a test session for individual horses (intra-subject). However, these profiles are more variable across horses (inter-subject) and between sessions (between-session reliability), suggesting that it is reasonable to use sEMG to objectively monitor the intra-individual activity of these muscles across multiple gait evaluation sessions at in-hand trot.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Centre for Applied Sport and Exercise Sciences, University of Central Lancashire, Preston, Lancashire, United Kingdom.
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
- Delsys/Altec Inc., Natick, Massachusetts, United States of America.
- Sport Horse Science, Mason, Michigan, United States of America.
- Allied Health Research Unit, University of Central Lancashire, Preston, Lancashire, United Kingdom.
ORCID-Profile: L St George, T J P Spoormakers, S J Hobbs
Förderung
- Morris Animal Foundation
- British Society of Animal Science
Zitieren
APA
St George, L., Spoormakers, T. J. P., Roy, S. H., Hobbs, S. J., Clayton, H. M., Richards, J., & Serra Bragança, F. M. (2023). Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot. PLOS ONE, 18(7), e0288664. https://doi.org/10.1371/journal.pone.0288664
Vancouver
St George L, Spoormakers TJP, Roy SH, Hobbs SJ, Clayton HM, Richards J, et al. Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot. PLOS ONE. 2023;18(7):e0288664. doi:10.1371/journal.pone.0288664
BibTeX
@article{StGeorge2023,
author = {St George, L and Spoormakers, T J P and Roy, S H and Hobbs, S J and Clayton, H M and Richards, J and Serra Bragança, F M},
title = {Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot},
journal = {PLOS ONE},
year = {2023},
volume = {18},
number = {7},
pages = {e0288664},
doi = {10.1371/journal.pone.0288664}
}
EUVIMED