EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity and reliability of upper body push and pull tests to determine one-repetition maximum

Eirik Sigvaldsen, Irineu Loturco iD, Fredrik Larsen, Jo Bruusgaard, John Magne Kalhovde, Thomas Haugen iD

PLOS ONE · 13.07.2023 · 18 (7) · e0288649

DOI: 10.1371/journal.pone.0288649 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 13.07.2023. Verfasst von Eirik Sigvaldsen und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Sciences, Kristiania University College, Oslo, Norway. Hauptthemen laut MEDLINE: Weight Lifting, Resistance Training. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bergesen Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The purpose of this study was to explore the validity and reliability of three different strength testing approaches to determine one-repetition maximum (1RM) in the bench press and prone bench pull.

Methods

Twenty-eight recreationally active subjects (25 ± 2 years, 178 ± 8 cm, 78 ± 9 kg) were assessed for load-velocity (L-V) relationship, 1RM, maximal isometric force (MIF), and maximal repetitions to failure (MRF) in a Smith Machine on three separated sessions. Linear regression was used for L-V relationship, MIF, and MRF to predict 1RM. Level of significance was set to ρ ≤ 0.05.

Results

Reliability analyses of the varying 1RM estimations revealed mean differences from 0.6 to -1.3 kg (mainly trivial effects) between test days 1 and 2, intraclass correlation coefficient was > 0.96, and coefficient of variation (CV) was in the range 2.3–8.3% for all tests. Regarding validity, all 1RM predictions exhibited a mean difference ≤ 1.3 kg (trivial), except for the L-V relationship method that underestimated the predicted 1RM by 5 kg (small) compared to the actual bench press 1RM. However, the L-V relationship method showed the least mean absolute errors. CVs were in the range 4.5–13.2%. Standard error of the estimate was in the range 3.2–9.7 kg. Change scores for all tests were significantly correlated with change scores in actual 1RM, except for MIF in the prone bench pull. Smallest deviations in 1RM predictions were observed for the L-V relationship approach.

Conclusions

All 1RM prediction methods were highly comparable to the traditional 1RM test. However, given the high variability associated with individual predictions for each method, they cannot be used interchangeably.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Weight LiftingResistance TrainingHumansReproducibility of ResultsMuscle StrengthLinear Models

Autor:innen und Institutionen

  • School of Health Sciences, Kristiania University College, Oslo, Norway.
  • NAR-Nucleus of High Performance in Sport, São Paulo, Brazil.

ORCID-Profile: Irineu Loturco, Thomas Haugen

Förderung

  • Bergesen Foundation

Zitieren

APA

Sigvaldsen, E., Loturco, I., Larsen, F., Bruusgaard, J., Kalhovde, J. M., & Haugen, T. (2023). Validity and reliability of upper body push and pull tests to determine one-repetition maximum. PLOS ONE, 18(7), e0288649. https://doi.org/10.1371/journal.pone.0288649

Vancouver

Sigvaldsen E, Loturco I, Larsen F, Bruusgaard J, Kalhovde JM, Haugen T. Validity and reliability of upper body push and pull tests to determine one-repetition maximum. PLOS ONE. 2023;18(7):e0288649. doi:10.1371/journal.pone.0288649

BibTeX
@article{Sigvaldsen2023,
  author = {Sigvaldsen, Eirik and Loturco, Irineu and Larsen, Fredrik and Bruusgaard, Jo and Kalhovde, John Magne and Haugen, Thomas},
  title = {Validity and reliability of upper body push and pull tests to determine one-repetition maximum},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {7},
  pages = {e0288649},
  doi = {10.1371/journal.pone.0288649}
}
Kostenlos starten →