Experimental study on pore structure characteristics and thermal conductivity of fibers reinforced foamed concrete
PLOS ONE · 07.07.2023 · 18 (7) · e0287690
DOI: 10.1371/journal.pone.0287690 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 07.07.2023. Verfasst von Lin Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Architectural Engineering, Suqian College, Suqian, China. Hauptthemen laut MEDLINE: Coal Ash, Plant Proteins. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The pore structure characteristics and thermal conductivity of foamed concrete (FC) reinforced with glass fibers (GF), polyvinyl alcohol fibers (PVAF) and polypropylene fibers (PPF) were investigated experimentally in this article. Firstly, GF, PVAF or PPF with different mass fractions (0%, 1%, 1.5% and 2%) were added to the Portland cement, fly ash and plant protein foaming agent to prepare the FC. Then, SEM tests, dry density tests, porosity tests, and thermal conductivity tests were carried out on FRFC. Later, the adhesion of GF, PVAF and FFF with different mass fractions to the cementitious base was investigated by SEM images of FRFC. The pore size distribution, shape factor and porosity of FRFC were analyzed using Photoshop software and Image Pro Plus (IPP) software. Finally, the effects of different mass fractions and lengths of three types of fibers on the thermal conductivity of FRFC were discussed. The results indicated that proper fiber mass fraction can play a role of refining small pores and separating large pores, improving the structural compactness, reducing the pore collapse phenomenon and optimizing the pore structure of FRFC. The three types of fibers can promote the optimization of cellular roundness and increase the proportion of pores with diameters below 400 μm. The FC with larger porosity had smaller dry density. As the fiber mass fraction increased, the thermal conductivity performed a phenomenon of first decrease and then increase. The three types of fibers with 1% mass fraction achieved relatively low thermal conductivity. Compared with the FC without fibers, the thermal conductivities of GF reinforced FC, PVAF reinforced FC and PPF reinforced FC with 1% mass fraction were decreased by 20.73%, 18.23% and 7.00%, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Architectural Engineering, Suqian College, Suqian, China.
- Jiangsu Province Engineering Research Center of Prefabricated Building and Intelligent Construction, Suqian, China.
- College of Material Science and Engineering, Nanjing Tech University, Nanjing, China.
- School of Transportation and Civil Engineering, Nantong University, Nantong, China.
ORCID-Profile: Mei-Ling Zhuang
Zitieren
APA
Li, L., Wang, W., Wang, Y., Li, D., & Zhuang, M. L. (2023). Experimental study on pore structure characteristics and thermal conductivity of fibers reinforced foamed concrete. PLOS ONE, 18(7), e0287690. https://doi.org/10.1371/journal.pone.0287690
Vancouver
Li L, Wang W, Wang Y, Li D, Zhuang ML. Experimental study on pore structure characteristics and thermal conductivity of fibers reinforced foamed concrete. PLOS ONE. 2023;18(7):e0287690. doi:10.1371/journal.pone.0287690
BibTeX
@article{Li2023,
author = {Li, Lin and Wang, Wei and Wang, Yu and Li, Dongxu and Zhuang, Mei-Ling},
title = {Experimental study on pore structure characteristics and thermal conductivity of fibers reinforced foamed concrete},
journal = {PLOS ONE},
year = {2023},
volume = {18},
number = {7},
pages = {e0287690},
doi = {10.1371/journal.pone.0287690}
}
EUVIMED