Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 04.05.2023. Verfasst von Stephanie G Fulton und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pacific Northwest National Laboratory, Richland, Washington, United States of America. Hauptthemen laut MEDLINE: Reproducibility of Results. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: U.S. Department of Energy, Electric Power Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Reproducibility of ResultsCalibrationElectric Conductivity

Autor:innen und Institutionen

  • Pacific Northwest National Laboratory, Richland, Washington, United States of America.
  • Department of Crop and Soil Sciences, University of Georgia, Athens, Georgia, United States of America.
  • School of the Environment, Washington State University, Pullman, Washington, United States of America.
  • Geology Department, University of Georgia, Athens, Georgia, United States of America.

ORCID-Profile: Stephanie G Fulton

Förderung

  • U.S. Department of Energy
  • Electric Power Research Institute

Zitieren

APA

Fulton, S. G., Stegen, J. C., Kaufman, M. H., Dowd, J., & Thompson, A. (2023). Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?. PLOS ONE, 18(5), e0285092. https://doi.org/10.1371/journal.pone.0285092

Vancouver

Fulton SG, Stegen JC, Kaufman MH, Dowd J, Thompson A. Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?. PLOS ONE. 2023;18(5):e0285092. doi:10.1371/journal.pone.0285092

BibTeX
@article{Fulton2023,
  author = {Fulton, Stephanie G and Stegen, James C and Kaufman, Matthew H and Dowd, John and Thompson, Aaron},
  title = {Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {5},
  pages = {e0285092},
  doi = {10.1371/journal.pone.0285092}
}
Kostenlos starten →