Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 15.08.2023. Verfasst von Daniela Oliveira Pontes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Nursing, Federal University of Goiás, Catalão, Brazil. Hauptthemen laut MEDLINE: Infection Control, Adenosine Triphosphate. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Timely detection of cleaning failure is critical for quality assurance within Sterilising Service Units (SSUs). Rapid Adenosine Triphosphate (ATP) testing provides a real time and quantitative indication of cellular contaminants, when used to measure surface or device cleanliness. The aim of this study was to investigate the use of an ATP algorithm and to whether it could be used as a routine quality assurance step, to monitor surgical instruments cleanliness in SSUs prior to sterilisation.

Methods

Cleanliness monitoring using rapid ATP testing was undertaken in the SSUs of four hospitals located in the western (Amazonia) region of Brazil. ATP testing was conducted (Clean Trace, 3M) on 163 surgical instruments, following manual cleaning. A sampling algorithm using a duplicate swab approach was applied to indicate surgical instruments as (i) very clean, (ii) clean, (iii) equivocal or (iv) fail, based around a ‘clean’ cut-off of 250 Relative Light Units (RLU) and a ‘very clean’

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Infection ControlAdenosine TriphosphateHumansSterilizationHospitalsSurgical Instruments

Substanzen

Adenosine Triphosphate

Autor:innen und Institutionen

  • Faculty of Nursing, Federal University of Goiás, Catalão, Brazil.
  • Nursing Department, Federal University of Rondônia, Porto Velho, Brazil.
  • Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia.
  • Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
  • School of Medicine, Western Sydney University, Penrith, Australia.
  • Whiteley Corporation, Kewdale, Australia.

ORCID-Profile: Daniela Oliveira Pontes, Priscilla Perez da Silva Pereira, Anaclara Ferreira Veiga Tipple

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Pontes, D. O., Costa, D. M., da Silva Pereira, P. P., Whiteley, G. S., Glasbey, T., & Tipple, A. F. V. (2023). Adenosine triphosphate (ATP) sampling algorithm for monitoring the cleanliness of surgical instruments. PLOS ONE, 18(8), e0284967. https://doi.org/10.1371/journal.pone.0284967

Vancouver

Pontes DO, Costa DM, da Silva Pereira PP, Whiteley GS, Glasbey T, Tipple AFV. Adenosine triphosphate (ATP) sampling algorithm for monitoring the cleanliness of surgical instruments. PLOS ONE. 2023;18(8):e0284967. doi:10.1371/journal.pone.0284967

BibTeX
@article{Pontes2023,
  author = {Pontes, Daniela Oliveira and Costa, Dayane de Melo and da Silva Pereira, Priscilla Perez and Whiteley, Greg S and Glasbey, Trevor and Tipple, Anaclara Ferreira Veiga},
  title = {Adenosine triphosphate (ATP) sampling algorithm for monitoring the cleanliness of surgical instruments},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {8},
  pages = {e0284967},
  doi = {10.1371/journal.pone.0284967}
}
Kostenlos starten →