Effect of geometric distortion correction on thickness and volume measurements of cortical parcellations in 3D T1w gradient echo sequences

Christian Thaler iD, Jan Sedlacik, Nils D Forkert, Jan-Patrick Stellmann, Gerhard Schön, Jens Fiehler, Susanne Gellißen

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0284440 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Christian Thaler und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Nervous System Diseases. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Automated brain volumetric analysis based on high-resolution T1-weighted MRI datasets is a frequently used tool in neuroimaging for early detection, diagnosis, and monitoring of various neurological diseases. However, image distortions can corrupt and bias the analysis. The aim of this study was to explore the variability of brain volumetric analysis due to gradient distortions and to investigate the effect of distortion correction methods implemented on commercial scanners. Material and methods 36 healthy volunteers underwent brain imaging using a 3T magnetic resonance imaging (MRI) scanner, including a high-resolution 3D T1-weighted sequence. For all participants, each T1-weighted image was reconstructed directly on the vendor workstation with (DC) and without (nDC) distortion correction. For each participant’s set of DC and nDC images, FreeSurfer was used for the determination of regional cortical thickness and volume.

Results

Overall, significant differences were found in 12 cortical ROIs comparing the volumes of the DC and nDC data and in 19 cortical ROIs comparing the thickness of the DC and nDC data. The most pronounced differences for cortical thickness were found in the precentral gyrus, the lateral occipital and postcentral ROI (2.69, -2.91% and -2.79%, respectively) while cortical volumes differed most prominently in the paracentral, the pericalcarine and lateral occipital ROI (5.52%, -5.40% and -5.11%, respectively).

Conclusion

Correcting for gradient non-linearities can have significant influence on volumetric analysis of cortical thickness and volume. Since the distortion correction is an automatic feature of the MR scanner, it should be stated by each study that applies volumetric analysis which images were used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingNervous System DiseasesHumansNeuroimagingImaging, Three-DimensionalBrain

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Biomedical Engineering Department, School of Biomedical Engineering & Imaging Sciences, King's College London, London, United Kingdom.
  • Department of Radiology, University of Calgary, Calgary, Canada.
  • Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Institute for Neuroimmunology and Multiple Sclerosis, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Department of Neuroradiology, APHM La Timone, CEMEREM, Marseille, France.

ORCID-Profile: Christian Thaler

Zitieren

APA

Thaler, C., Sedlacik, J., Forkert, N. D., Stellmann, J. P., Schön, G., Fiehler, J., & Gellißen, S. (2023). Effect of geometric distortion correction on thickness and volume measurements of cortical parcellations in 3D T1w gradient echo sequences. PLOS ONE. https://doi.org/10.1371/journal.pone.0284440

Vancouver

Thaler C, Sedlacik J, Forkert ND, Stellmann JP, Schön G, Fiehler J, et al. Effect of geometric distortion correction on thickness and volume measurements of cortical parcellations in 3D T1w gradient echo sequences. PLOS ONE. 2023. doi:10.1371/journal.pone.0284440

BibTeX
@article{Thaler2023,
  author = {Thaler, Christian and Sedlacik, Jan and Forkert, Nils D and Stellmann, Jan-Patrick and Schön, Gerhard and Fiehler, Jens and Gellißen, Susanne},
  title = {Effect of geometric distortion correction on thickness and volume measurements of cortical parcellations in 3D T1w gradient echo sequences},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0284440}
}
Kostenlos starten →