Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Cansu Cosgun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Erzincan, Turkey. Hauptthemen laut MEDLINE: Shoulder Joint, Dyskinesias. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Mobilisation
Abstract (Originalsprache)
Purpose
Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis. Materials and methods Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study.
Results
The shoulder’s mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG ( p = .016 and p = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG ( p = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG ( p = .002 and p < .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG ( p = .014 and p = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb.
Conclusion
The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Erzincan, Turkey.
- Medical Faculty, Department of Cardiology, Mengucek Gazi Education and Research Hospital, Erzincan Binali Yildirim University, Erzincan, Turkey.
- Department of Physical Therapy and Rehabilitation, Kırşehir Ahi Evran University, Kırşehir, Turkey.
ORCID-Profile: Cansu Cosgun
Zitieren
APA
Cosgun, C., Cosgun, M. S., Buyukturan, O., & Buyukturan, B. (2023). Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life. PLOS ONE. https://doi.org/10.1371/journal.pone.0284178
Vancouver
Cosgun C, Cosgun MS, Buyukturan O, Buyukturan B. Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life. PLOS ONE. 2023. doi:10.1371/journal.pone.0284178
BibTeX
@article{Cosgun2023,
author = {Cosgun, Cansu and Cosgun, Muharrem Said and Buyukturan, Oznur and Buyukturan, Buket},
title = {Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0284178}
}
EUVIMED