EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fluorescent microspheres can affect in vitro fibrinolytic outcomes

Ethan G Stoll, Sean J Cone, Spencer R Lynch iD, Andrew T Fuquay, Brittany E Bannish, Nathan E Hudson iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0284163 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Ethan G Stoll und 5 weiteren Autor:innen. Beteiligte Einrichtung: Dept. Physics, East Carolina University, Greenville, North Carolina, United States of America. Hauptthemen laut MEDLINE: Fibrinolysin, Thrombosis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NHLBI Division of Intramural Research, University of Central Oklahoma.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemostasis is the cessation of bleeding due to the formation of a blood clot. After the completion of wound healing, the blood clot is typically dissolved through the natural process of fibrinolysis, the enzymatic digestion by plasmin of the fibrin fibers that make up its structural scaffold. In vitro studies of fibrinolysis reveal mechanisms regulating these processes and often employ fluorescent microscopy to observe protein colocalization and fibrin digestion. In this study, we investigate the effects of labeling a fibrin network with 20 nm diameter fluorescent beads (fluorospheres) for the purpose of studying fibrinolysis. We observed fibers and 2-D fibrin networks labeled with fluorospheres during fibrinolysis. We found that the labeling of fibrin with fluorospheres can alter fibrinolytic mechanisms. In previous work, we showed that, during lysis, fibrin fibers are cleaved into two segments at a single location. Herein we demonstrate that fibrinolysis can be altered by the concentration of fluorospheres used to label the fibers, with high concentrations of fluorospheres leading to very minimal cleaving. Furthermore, fibers that are left uncleaved after the addition of plasmin often elongate, losing their inherent tension throughout the imaging process. Elongation was especially prominent among fibers that had bundled together due to other cleavage events and was dependent on the concentration of fluorophores used to label fibers. Of the fibers that do cleave, the site at which they cleave also shows a predictable trend dependent on fluorosphere concentration; low concentrations heavily favor cleavage locations at either end of fibrin fiber and high concentrations show no disparity between the fiber ends and other locations along the fiber. After the initial cleavage event bead concentration also affects further digestion, as higher bead concentrations exhibited a larger population of fibers that did not digest further. The results described in this paper indicate that fluorescent labeling strategies can impact fibrinolysis results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FibrinolysinThrombosisHumansMicrospheresFibrinolysisFibrin

Substanzen

FibrinolysinFibrin

Autor:innen und Institutionen

  • Dept. Physics, East Carolina University, Greenville, North Carolina, United States of America.
  • Department of Biological Sciences, North Carolina State University, Raleigh, North Carolina, United States of America.
  • Medical Physics Graduate Program, Duke University, Durham, North Carolina, United States of America.
  • Dept. Mathematics and Statistics, University of Central Oklahoma, Edmond, Oklahoma, United States of America.

ORCID-Profile: Spencer R Lynch, Nathan E Hudson

Förderung

  • NHLBI NIH HHS
  • NHLBI Division of Intramural Research
  • University of Central Oklahoma
  • East Carolina University

Zitieren

APA

Stoll, E. G., Cone, S. J., Lynch, S. R., Fuquay, A. T., Bannish, B. E., & Hudson, N. E. (2023). Fluorescent microspheres can affect in vitro fibrinolytic outcomes. PLOS ONE. https://doi.org/10.1371/journal.pone.0284163

Vancouver

Stoll EG, Cone SJ, Lynch SR, Fuquay AT, Bannish BE, Hudson NE. Fluorescent microspheres can affect in vitro fibrinolytic outcomes. PLOS ONE. 2023. doi:10.1371/journal.pone.0284163

BibTeX
@article{Stoll2023,
  author = {Stoll, Ethan G and Cone, Sean J and Lynch, Spencer R and Fuquay, Andrew T and Bannish, Brittany E and Hudson, Nathan E},
  title = {Fluorescent microspheres can affect in vitro fibrinolytic outcomes},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0284163}
}
Kostenlos starten →