EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ECG signal classification in wearable devices based on compressed domain

Jing Hua, Binbin Chu iD, Jiawen Zou, Jing Jia iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0284008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Jing Hua und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Software, Jiangxi Agricultural University, Nanchang, China. Hauptthemen laut MEDLINE: Data Compression, Wearable Electronic Devices. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable devices are often used to diagnose arrhythmia, but the electrocardiogram (ECG) monitoring process generates a large amount of data, which will affect the detection speed and accuracy. In order to solve this problem, many studies have applied deep compressed sensing (DCS) technology to ECG monitoring, which can under-sampling and reconstruct ECG signals, greatly optimizing the diagnosis process, but the reconstruction process is complex and expensive. In this paper, we propose an improved classification scheme for deep compressed sensing models. The framework is comprised of four modules: pre-processing; compression; and classification. Firstly, the normalized ECG signals are compressed adaptively in the three convolutional layers, and then the compressed data is directly put into the classification network to obtain the results of four kinds of ECG signals. We conducted our experiments on the MIT-BIH Arrhythmia Database and Ali Cloud Tianchi ECG signal Database to validate the robustness of our model, adopting Accuracy, Precision, Sensitivity and F1-score as the evaluation metrics. When the compression ratio (CR) is 0.2, our model has 98.16% accuracy, 98.28% average accuracy, 98.09% Sensitivity and 98.06% F1-score, all of which are better than other models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Data CompressionWearable Electronic DevicesHumansAlgorithmsElectrocardiographyArrhythmias, CardiacSignal Processing, Computer-Assisted

Autor:innen und Institutionen

  • School of Software, Jiangxi Agricultural University, Nanchang, China.
  • School of Computer and Information Engineering, Jiangxi Agricultural University, Nanchang, China.

ORCID-Profile: Binbin Chu, Jing Jia

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangxi Province

Zitieren

APA

Hua, J., Chu, B., Zou, J., & Jia, J. (2023). ECG signal classification in wearable devices based on compressed domain. PLOS ONE. https://doi.org/10.1371/journal.pone.0284008

Vancouver

Hua J, Chu B, Zou J, Jia J. ECG signal classification in wearable devices based on compressed domain. PLOS ONE. 2023. doi:10.1371/journal.pone.0284008

BibTeX
@article{Hua2023,
  author = {Hua, Jing and Chu, Binbin and Zou, Jiawen and Jia, Jing},
  title = {ECG signal classification in wearable devices based on compressed domain},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0284008}
}
Kostenlos starten →