EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of circumferential ankle pressure of shoe collar on the kinematics, dynamic stability, electromyography, and plantar pressure during normal walking

Alireza Nasirzadeh iD, Seung-Tae Yang, Juseok Yun, Jaeha Yang, Young Yoon Bae, Juyeon Park, Jooeun Ahn iD, Giuk Lee iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0281684 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Alireza Nasirzadeh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Chung-Ang University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Ankle, Shoes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Industrial Strategic Technology Development Program, Chung-Ang University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The shoe’s collar plays a significant role in supporting the ankle during walking. Since the protective effect of the collar requires the circular embracing of the ankle and shank, a stiffer collar might be involved with increased circumferential ankle pressure (CAP). It is not clear how collar CAP affects walking performance. Therefore, this study was aimed at examining the influence of the collar CAP on the kinematics, dynamic stability, electromyography (EMG), and plantar pressure during normal walking.

Method

Sixteen healthy male participants walked on a treadmill while wearing a custom-designed high-collar shoe with 10 (low), 30 (medium), and 60 mmHg (high) CAP conditions, and the joint angles, dynamic stability index, EMG, and plantar pressure were measured.

Result

While the low CAP condition did not affect the ankle range of motion (ROM), The high CAP condition restricted both the ankle sagittal and frontal ROM, whereas the medium CAP condition limited only the ankle frontal ROM. The knee and hip ROM did not differ between conditions. The dynamic stability for the high and medium CAP cases was comparable but significantly higher than that of the low CAP condition. The ankle muscle activity and corresponding co-contraction increased with increasing CAP for gastrocnemius medialis (GM), soleus (SOL), peroneus longus (PL), tibialis anterior (TA) muscles in the weight acceptance and push-off phases but not in the single limb support. Knee muscle activity, including vastus lateralis (VL) and semitendinosus (SEMI) was similar between all conditions. A higher relative pressure was observed under the lateral aspect of the heel when walking in the high CAP condition.

Conclusion

The results suggest that a high-collar shoe with a high CAP may not be an appropriate choice for walking owing to the injury risk factors and limited walking efficiency. A medium CAP is associated with certain advantages and, thus, a superior choice for high-collar shoe design.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnkleShoesMaleHumansElectromyographyBiomechanical PhenomenaWalkingAnkle JointMuscle, SkeletalGait

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Chung-Ang University, Seoul, Republic of Korea.
  • Department of Textiles, Merchandising and Fashion Design, Seoul National University, Seoul, Republic of Korea.
  • Department of Physical Education, Seoul National University, Seoul, Republic of Korea.

ORCID-Profile: Alireza Nasirzadeh, Jooeun Ahn, Giuk Lee

Förderung

  • Industrial Strategic Technology Development Program
  • Chung-Ang University

Zitieren

APA

Nasirzadeh, A., Yang, S. T., Yun, J., Yang, J., Yoon Bae, Y., Park, J., Ahn, J., & Lee, G. (2023). Influence of circumferential ankle pressure of shoe collar on the kinematics, dynamic stability, electromyography, and plantar pressure during normal walking. PLOS ONE. https://doi.org/10.1371/journal.pone.0281684

Vancouver

Nasirzadeh A, Yang ST, Yun J, Yang J, Yoon Bae Y, Park J, et al. Influence of circumferential ankle pressure of shoe collar on the kinematics, dynamic stability, electromyography, and plantar pressure during normal walking. PLOS ONE. 2023. doi:10.1371/journal.pone.0281684

BibTeX
@article{Nasirzadeh2023,
  author = {Nasirzadeh, Alireza and Yang, Seung-Tae and Yun, Juseok and Yang, Jaeha and Yoon Bae, Young and Park, Juyeon and Ahn, Jooeun and Lee, Giuk},
  title = {Influence of circumferential ankle pressure of shoe collar on the kinematics, dynamic stability, electromyography, and plantar pressure during normal walking},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0281684}
}
Kostenlos starten →