EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Capturing the attentional response to clinical auditory alarms: An ERP study on priority pulses

Vasco Ribeiro Ferreira iD, Ana Rita Pereira, Joana Vieira, Frederico Pereira, Rui Marques, Guilherme Campos iD, Adriana Sampaio, Alberto Crego iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0281680 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Vasco Ribeiro Ferreira und 7 weiteren Autor:innen. Beteiligte Einrichtung: Psychological Neuroscience Laboratory (PNL), Research Center in Psychology (CIPsi), School of Psychology, University of Minho, Braga, Portugal. Hauptthemen laut MEDLINE: Clinical Alarms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Foundation for Science and Technology, FCT and the European Regional Development Fund, FCT and the Portuguese Ministry of Science, Technology and Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Clinical auditory alarms are often found in hospital wards and operating rooms. In these environments, regular daily tasks can result in having a multitude of concurrent sounds (from staff and patients, building systems, carts, cleaning devices, and importantly, patient monitoring devices) which easily amount to a prevalent cacophony. The negative impact of this soundscape on staff and patients’ health and well-being, as well as in their performance, demand for accordingly designed sound alarms. The recently updated IEC60601-1-8 standard, in guidance for medical equipment auditory alarms, proposed a set of pointers to distinctly convey medium or high levels of priority (urgency). However, conveying priority without compromising other features, such as ease of learnability and detectability, is an ongoing challenge. Electroencephalography, a non-invasive technique for measuring the brain response to a given stimulus, suggests that certain Event-Related Potentials (ERPs) components such as the Mismatch Negativity (MMN) and P3a may be the key to uncovering how sounds are processed at the pre-attentional level and how they may capture our attention. In this study, the brain dynamics in response to the priority pulses of the updated IEC60601-1-8 standard was studied via ERPs (MMN and P3a), for a soundscape characterised by the repetition of a sound (generic SpO2 “beep”), usually present in operating and recovery rooms. Additional behavioural experiments assessed the behavioural response to these priority pulses. Results showed that the Medium Priority pulse elicits a larger MMN and P3a peak amplitude when compared to the High Priority pulse. This suggests that, at least for the applied soundscape, the Medium Priority pulse is more easily detected and attended at the neural level. Behavioural data supports this indication, showing significantly shorter reaction times for the Medium Priority pulse. The results pose the possibility that priority pointers of the updated IEC60601-1-8 standard may not be successfully conveying their intended priority levels, which may not only be due to design properties but also to the soundscape in which these clinical alarms are deployed. This study highlights the need for intervention in both hospital soundscapes and auditory alarm design settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical AlarmsHumansEvoked PotentialsAttentionElectroencephalographyReaction TimeEvoked Potentials, AuditoryAcoustic StimulationAuditory Perception

Autor:innen und Institutionen

  • Psychological Neuroscience Laboratory (PNL), Research Center in Psychology (CIPsi), School of Psychology, University of Minho, Braga, Portugal.
  • Sustainable Health Department, Campus Fryslân, University of Groningen, Leeuwarden, Netherlands.
  • Ergonomics & Human Factors Group, ALGORITMI Research Centre, University of Minho, Guimarães, Portugal.
  • CIAUD Research Centre for Architecture Urbanism and Design, Lisbon School of Architecture, Universidade de Lisboa, Lisboa, Portugal.
  • Center for Computer Graphics (CCG), Guimarães, Portugal.
  • Institute of Electronics and Telematics Engineering, University of Aveiro, Aveiro, Portugal.

ORCID-Profile: Vasco Ribeiro Ferreira, Guilherme Campos, Alberto Crego

Förderung

  • Foundation for Science and Technology
  • FCT and the European Regional Development Fund
  • FCT and the Portuguese Ministry of Science, Technology and Higher Education

Zitieren

APA

Ribeiro Ferreira, V., Pereira, A. R., Vieira, J., Pereira, F., Marques, R., Campos, G., Sampaio, A., & Crego, A. (2023). Capturing the attentional response to clinical auditory alarms: An ERP study on priority pulses. PLOS ONE. https://doi.org/10.1371/journal.pone.0281680

Vancouver

Ribeiro Ferreira V, Pereira AR, Vieira J, Pereira F, Marques R, Campos G, et al. Capturing the attentional response to clinical auditory alarms: An ERP study on priority pulses. PLOS ONE. 2023. doi:10.1371/journal.pone.0281680

BibTeX
@article{RibeiroFerreira2023,
  author = {Ribeiro Ferreira, Vasco and Pereira, Ana Rita and Vieira, Joana and Pereira, Frederico and Marques, Rui and Campos, Guilherme and Sampaio, Adriana and Crego, Alberto},
  title = {Capturing the attentional response to clinical auditory alarms: An ERP study on priority pulses},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0281680}
}