Efficacy and safety of guide extension catheter in balloon pulmonary angioplasty for treatment of complex lesions in chronic thromboembolic pulmonary hypertension
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0280683 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Masao Takigami und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan. Hauptthemen laut MEDLINE: Hypertension, Pulmonary, Pulmonary Embolism, Angioplasty, Balloon. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Balloon pulmonary angioplasty (BPA) is used for treatment of inoperable chronic thromboembolic pulmonary hypertension (CTEPH) and residual pulmonary hypertension after pulmonary endarterectomy (PEA) to improve hemodynamics, right ventricular function, and exercise capacity. However, the effectiveness and safety of guide extension catheters for BPA treatment in patients with CTEPH have not been demonstrated.
Methods
We retrospectively analyzed 91 lesions in 55 sessions of 28 patients with CTEPH who underwent BPA using a guide extension catheter. The purpose (backup, coaxial, and extension), efficacy, and safety of the guide extension catheters were explored. The efficacy of the guide extension catheter was assessed based on the success of the procedures and safety was evaluated based on procedure-related complications.
Results
Regarding the intended use, a guide extension catheter was used to strengthen the backup force of the guiding catheter in 52% of cases, extend the tip of the catheter in 38% of cases, and maintain the coaxiality of the guiding catheter in 10% of cases. Procedural success was achieved in 92.7% of 55 sessions and in 95.6% of 91 lesions. Complex lesions had a lower success rate than simple lesions (p = 0.04). Regarding safety concerns, complications were observed in 5 of 55 sessions (9.1%) and 6 of 91 lesions (6.6%). Only one case of pulmonary artery dissection using a guide extension catheter was reported. Except for this one case, extension catheter-related complications were not observed.
Conclusions
A guide extension catheter can be used safely in BPA procedures with anatomically complex pulmonary artery branches and complex lesions by increasing backup support.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
- Department of Cardiovascular Medicine, Omihachiman Community Medical Center, Shiga, Japan.
ORCID-Profile: Naohiko Nakanishi
Zitieren
APA
Takigami, M., Nakanishi, N., Tsubata, H., Fukai, K., Matsubara, Y., Yanishi, K., Zen, K., Nakamura, T., & Matoba, S. (2023). Efficacy and safety of guide extension catheter in balloon pulmonary angioplasty for treatment of complex lesions in chronic thromboembolic pulmonary hypertension. PLOS ONE. https://doi.org/10.1371/journal.pone.0280683
Vancouver
Takigami M, Nakanishi N, Tsubata H, Fukai K, Matsubara Y, Yanishi K, et al. Efficacy and safety of guide extension catheter in balloon pulmonary angioplasty for treatment of complex lesions in chronic thromboembolic pulmonary hypertension. PLOS ONE. 2023. doi:10.1371/journal.pone.0280683
BibTeX
@article{Takigami2023,
author = {Takigami, Masao and Nakanishi, Naohiko and Tsubata, Hideo and Fukai, Kuniyoshi and Matsubara, Yuki and Yanishi, Kenji and Zen, Kan and Nakamura, Takeshi and Matoba, Satoaki},
title = {Efficacy and safety of guide extension catheter in balloon pulmonary angioplasty for treatment of complex lesions in chronic thromboembolic pulmonary hypertension},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0280683}
}
EUVIMED