Genome concentration, characterization, and integrity analysis of recombinant adeno-associated viral vectors using droplet digital PCR
PLOS ONE · 25.01.2023 · 18 (1) · e0280242
DOI: 10.1371/journal.pone.0280242 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 25.01.2023. Verfasst von Andrew Prantner und 1 weiteren Autor:innen. Beteiligte Einrichtung: Digital Biology Group, Bio-Rad Laboratories, Inc., Pleasanton, California, United States of America. Hauptthemen laut MEDLINE: Genetic Vectors, Dependovirus. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Precise, reproducible characterization of AAV is critical for comparing preclinical results between laboratories and determining a safe and effective clinical dose for gene therapy applications. In this study, we systematically evaluated numerous parameters to produce a simple and robust ddPCR protocol for AAV characterization. The protocol uses a low ionic strength buffer containing Pluronic-F68 and polyadenylic acid to dilute the AAV into the ddPCR concentration range and a 10-minute thermal capsid lysis prior to assembling ddPCR reactions containing MspI. A critical finding is that the buffer composition affected the ITR concentration of AAV but not the ITR concentration of a double stranded plasmid, which has implications when using a theoretical, stoichiometric conversion factor to obtain the titer based on the ITR concentration. Using this protocol, a more comprehensive analysis of an AAV vector formulation was demonstrated with multiple ddPCR assays distributed throughout the AAV vector genome. These assays amplify the ITR, regulatory elements, and eGFP transgene to provide a more confident estimate of the vector genome concentration and a high-resolution characterization of the vector genome identity. Additionally, we compared two methods of genome integrity analysis for three control sample types at eight different concentrations for each sample. The genome integrity was independent of sample concentration and the expected values were obtained when integrity was determined based on the excess number of positive droplets relative to the number of double positive droplets expected by chance co-encapsulation of two DNA targets. The genome integrity was highly variable and produced unexpected values when the double positive droplet percentage was used to calculate the genome integrity. A protocol using a one-minute thermal capsid lysis prior to assembling ddPCR reactions lacking a restriction enzyme used the non-ITR assays in a duplex ddPCR milepost experiment to determine the genome integrity using linkage analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Digital Biology Group, Bio-Rad Laboratories, Inc., Pleasanton, California, United States of America.
ORCID-Profile: Andrew Prantner
Zitieren
APA
Prantner, A., & Maar, D. (2023). Genome concentration, characterization, and integrity analysis of recombinant adeno-associated viral vectors using droplet digital PCR. PLOS ONE, 18(1), e0280242. https://doi.org/10.1371/journal.pone.0280242
Vancouver
Prantner A, Maar D. Genome concentration, characterization, and integrity analysis of recombinant adeno-associated viral vectors using droplet digital PCR. PLOS ONE. 2023;18(1):e0280242. doi:10.1371/journal.pone.0280242
BibTeX
@article{Prantner2023,
author = {Prantner, Andrew and Maar, Dianna},
title = {Genome concentration, characterization, and integrity analysis of recombinant adeno-associated viral vectors using droplet digital PCR},
journal = {PLOS ONE},
year = {2023},
volume = {18},
number = {1},
pages = {e0280242},
doi = {10.1371/journal.pone.0280242}
}