EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Fetoscopic endoluminal tracheal occlusion with Smart-TO balloon: Study protocol to evaluate effectiveness and safety of non-invasive removal

Nicolas Sananès iD, David Basurto iD, Anne-Gaël Cordier, Caroline Elie, Francesca Maria Russo, Alexandra Benachi, Jan Deprest

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0273878 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift PLOS ONE, 2023. Verfasst von Nicolas Sananès und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maternal Fetal Medicine, Strasbourg University Hospital, Strasbourg, France. Hauptthemen laut MEDLINE: Hernias, Diaphragmatic, Congenital, Balloon Occlusion, Airway Obstruction. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Erasmus+, Great Ormond Street Hospital Charity, Assistance Publique - Hôpitaux de Paris.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

One of the drawbacks of fetoscopic endoluminal tracheal occlusion (FETO) for congenital diaphragmatic hernia is the need for a second invasive intervention to reestablish airway patency. The “Smart-TO” (Strasbourg University-BSMTI, France) is a new balloon for FETO, which spontaneously deflates when positioned near a strong magnetic field, e.g., generated by a magnetic resonance image (MRI) scanner. Translational experiments have demonstrated its efficacy and safety. We will now use the Smart-TO balloon for the first time in humans. Our main objective is to evaluate the effectiveness of prenatal deflation of the balloon by the magnetic field generated by an MRI scanner. Material and methods These studies were first in human (patients) trials conducted in the fetal medicine units of Antoine–Béclère Hospital, France, and UZ Leuven, Belgium. Conceived in parallel, protocols were amended by the local Ethics Committees, resulting in some minor differences. These trials were single-arm interventional feasibility studies. Twenty (France) and 25 (Belgium) participants will have FETO with the Smart-TO balloon. Balloon deflation will be scheduled at 34 weeks or earlier if clinically required. The primary endpoint is the successful deflation of the Smart-TO balloon after exposure to the magnetic field of an MRI. The secondary objective is to report on the safety of the balloon. The percentage of fetuses in whom the balloon is deflated after exposure will be calculated with its 95% confidence interval. Safety will be evaluated by reporting the nature, number, and percentage of serious unexpected or adverse reactions.

Conclusion

These first in human (patients) trials may provide the first evidence of the potential to reverse the occlusion by Smart-TO and free the airways non-invasively, as well a safety data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernias, Diaphragmatic, CongenitalBalloon OcclusionAirway ObstructionPregnancyFemaleHumansTracheaFetoscopyFetusPerinatology

Autor:innen und Institutionen

  • Department of Maternal Fetal Medicine, Strasbourg University Hospital, Strasbourg, France.
  • INSERM 1121 'Biomaterials and Bioengineering', Strasbourg University, Strasbourg, France.
  • MyFetUZ Fetal Research Center, Department of Development and Regeneration, Cluster Woman and Child, Biomedical Sciences, KU Leuven, Leuven, Belgium.
  • Department of Maternal fetal Medicine, Antoine-Béclère Hospital - Paris-Saclay University, Clamart, France.
  • Clinical Research Unit/Clinical Investigation Center, Necker-Enfants Malades Hospital, Paris, France.
  • Clinical Department of Obstetrics and Gynaecology, University Hospitals Leuven, Leuven, Belgium.

ORCID-Profile: Nicolas Sananès, David Basurto

Förderung

  • Erasmus+
  • Great Ormond Street Hospital Charity
  • Assistance Publique - Hôpitaux de Paris
  • Universitaire Ziekenhuizen Leuven, KU Leuven

Zitieren

APA

Sananès, N., Basurto, D., Cordier, A. G., Elie, C., Russo, F. M., Benachi, A., & Deprest, J. (2023). Fetoscopic endoluminal tracheal occlusion with Smart-TO balloon: Study protocol to evaluate effectiveness and safety of non-invasive removal. PLOS ONE. https://doi.org/10.1371/journal.pone.0273878

Vancouver

Sananès N, Basurto D, Cordier AG, Elie C, Russo FM, Benachi A, et al. Fetoscopic endoluminal tracheal occlusion with Smart-TO balloon: Study protocol to evaluate effectiveness and safety of non-invasive removal. PLOS ONE. 2023. doi:10.1371/journal.pone.0273878

BibTeX
@article{Sanans2023,
  author = {Sananès, Nicolas and Basurto, David and Cordier, Anne-Gaël and Elie, Caroline and Russo, Francesca Maria and Benachi, Alexandra and Deprest, Jan},
  title = {Fetoscopic endoluminal tracheal occlusion with Smart-TO balloon: Study protocol to evaluate effectiveness and safety of non-invasive removal},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0273878}
}
Kostenlos starten →