Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study
PLOS Neglected Tropical Diseases · 2025
DOI: 10.1371/journal.pntd.0012310 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift PLOS Neglected Tropical Diseases, 2025. Verfasst von Inge Van Damme und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Translational Physiology, Infectiology and Public Health, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium. Hauptthemen laut MEDLINE: Cysticercosis, Point-of-Care Testing, Taenia solium, Taeniasis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: European & Developing Countries Clinical Trials Partnership, German Federal Ministry of Education and Research, European and Developing Countries Clinical Trials Partnership.
Abstract (Originalsprache)
The TS POC test, Taenia solium point-of-care test, is a two-strip lateral flow assay using the recombinant antigen rES33 on the TS POC T test strip, and rT24H on the TS POC CC test strip, to detect antibodies against T. solium taeniosis and cysticercosis, respectively. The objective of this study was to assess the diagnostic performance of the TS POC test for the detection of T. solium taeniosis and cysticercosis in individuals attending district hospitals in Tanzania. In this prospective two-phase diagnostic accuracy study, we recruited participants aged 10 and above, excluding pregnant women and those with acute severe illness. Participants were consecutively recruited in three cohorts according to their signs/symptoms: compatible with neurocysticercosis (cohort 1), intestinal worm infections (cohort 2), and other signs/symptoms (cohort 3). Lacking a gold standard test for both infections, diagnostic accuracy was evaluated using results of two coprological and two serological tests for taeniosis, and three serological tests for cysticercosis, in a Bayesian Latent Class Model approach. The TS POC test was conducted on 601 participants in cohort 1, 1661 participants in cohort 2, and 662 participants in cohort 3. Most individuals tested negative on both TS POC test strips, with proportions of 83% (n = 496), 97% (n = 1613) and 97% (n = 641) in cohorts 1, 2 and 3, respectively. Complete case data were available for 120, 114, and 53 participants for taeniosis, and 126, 122, and 55 participants for cysticercosis. Sensitivity values for the TS POC T test strip were 50.2% [95% credible interval 4.9 - 96.4], 40.8% [2.2 - 95.2], and 40.4% [2.3 – 95.0], while specificity values were 98.6% [97.1 - 99.6], 99.3% [98.7 - 99.7] and 99.4% [98.5 - 99.9], respectively. For the TS POC CC test strip, the sensitivity was 77.5% [37.8 - 99.2], 24.9% [95% CI 6.4 - 52.7] and 44.2% [6.6 - 91.5], and the specificity 92.3% [86.5 - 98.8], 99.1% [97.8 - 100], and 98.1% [96.1 - 99.7] across the respective cohorts. Although the TS POC test has a low sensitivity, it demonstrates a high specificity, which may have clinical utility to guide treatment and diagnostic decisions, or in epidemiological studies. An important strength of this study lies in its assessment of the TS POC test under real-world conditions, revealing divergent estimates across distinct cohorts. The study underscores the suboptimal performance of existing tests under field conditions, emphasizing the need to enhance and validate these tests for better performance in practical real-world settings. Registration number: PACTR201712002788898.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Translational Physiology, Infectiology and Public Health, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
- Service Foodborne Pathogens, Sciensano, Brussels, Belgium.
- Department of Public Health, Institute of Tropical Medicine, Antwerp, Belgium.
- Tanzania Livestock Research Institute (TALIRI), Central Zone Office, Mpwapwa, Dodoma, Tanzania.
- Department of Neurology, Center for Global Health, Technical University of Munich, Munich, Germany.
- National Institute for Medical Research, Muhimbili Medical Research Centre, Dar es Salaam, Tanzania.
ORCID-Profile: Inge Van Damme
Förderung
- European & Developing Countries Clinical Trials Partnership
- German Federal Ministry of Education and Research
- European and Developing Countries Clinical Trials Partnership
- Bundesministerium für Bildung und Forschung
Zitieren
APA
Van Damme, I., Trevisan, C., Kabululu, M., Stelzle, D., Makasi, C. E., Schmidt-Urbaneja, V., Mwape, K. E., Mubanga, C., Zulu, G., Møller, K. S., Jansen, F., Reynders, D., Noh, J., Handali, S., Bottieau, E., Winkler, A. S., Dorny, P., Magnussen, P., Gabriël, S., & Ngowi, B. (2025). Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study. PLOS Neglected Tropical Diseases. https://doi.org/10.1371/journal.pntd.0012310
Vancouver
Van Damme I, Trevisan C, Kabululu M, Stelzle D, Makasi CE, Schmidt-Urbaneja V, et al. Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study. PLOS Neglected Tropical Diseases. 2025. doi:10.1371/journal.pntd.0012310
BibTeX
@article{VanDamme2025,
author = {Van Damme, Inge and Trevisan, Chiara and Kabululu, Mwemezi and Stelzle, Dominik and Makasi, Charles E and Schmidt-Urbaneja, Veronika and Mwape, Kabemba E and Mubanga, Chishimba and Zulu, Gideon and Møller, Karen Shou and Jansen, Famke and Reynders, Dries and Noh, John and Handali, Sukwan and Bottieau, Emmanuel and Winkler, Andrea S and Dorny, Pierre and Magnussen, Pascal and Gabriël, Sarah and Ngowi, Bernard},
title = {Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study},
journal = {PLOS Neglected Tropical Diseases},
year = {2025},
doi = {10.1371/journal.pntd.0012310}
}
EUVIMED