Analysis of diagnostic test outcomes in a large loiasis cohort from an endemic region: Serological tests are often false negative in hyper-microfilaremic infections
PLOS Neglected Tropical Diseases · 2024
DOI: 10.1371/journal.pntd.0012054 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Neglected Tropical Diseases, 2024. Verfasst von Luzia Veletzky und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine I, Division of Infectious Diseases and Tropical Medicine, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Loiasis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Science, Research and Economy of Austria, German Center for Infection research, Bundesministerium für Wissenschaft, Forschung und Wirtschaft.
Abstract (Originalsprache)
Background
The parasitic disease loiasis is associated with significant morbidity and mortality. Individuals with hyper-microfilaremia (greater than 20,000 microfilariae per mL of blood) may suffer from serious treatment-related or spontaneous adverse events. Diagnosing loiasis remains complex and primarily relies on direct parasite detection. In this study, we analyzed the performance of various diagnostic tests and the influence of parasitological and clinical factors on test outcomes in samples from individuals living in an endemic region.
Methods
Data and samples were collected from rural Gabon. Loiasis was defined as either detectable microfilaremia, or a positive history of eyeworm as assessed by the RAPLOA questionnaire. Diagnostic testing included a quantitative PCR (qPCR) for detection of Loa loa DNA in blood samples, an in-house crude L . loa antigen IgG ELISA, and a rapid test for antibodies against the Ll-SXP-1 antigen (RDT). Sensitivity and specificity were determined for each test and factors potentially influencing outcomes were evaluated in an exploratory analysis.
Results
ELISA, RDT and qPCR results were available for 99.8%, 78.5%, and 100% of the 1,232 participants, respectively. The ELISA and RDT had only modest diagnostic accuracy. qPCR was specific for L . loa microfilaremia and Cycle threshold values correlated with microfilarial density. Anti- L . loa IgG levels were highest in occult loiasis, and antibody levels correlated inversely with L . loa microfilarial density as did RDT line intensities. Only 84.6% and 16.7% of hyper-microfilaremic individuals tested positive by ELISA (11/13) and RDT (2/12), respectively.
Conclusion
None of the tests demonstrated high sensitivity and specificity for loiasis. Indirect diagnostic assays were characterized by low specificity. Additionally, hyper-microfilaremic individuals often tested negative by RDT and ELISA, indicating that these tests are not suitable for individual case management in endemic populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medicine I, Division of Infectious Diseases and Tropical Medicine, Medical University of Vienna, Vienna, Austria.
- Department of Tropical Medicine, Bernhard Nocht Institute for Tropical Medicine & I. Dep. of Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Centre de Recherches Médicales de Lambaréné, Lambaréné, Gabon.
- German Center for Infection Research (DZIF), Hamburg-Lübeck-Borstel-Riems, Germany.
- Department of Urology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Institute of Tropical Medicine, University of Tübingen, Tübingen, Germany & German Center for Infection Research, partner site Tübingen, Tübingen, Germany.
ORCID-Profile: Luzia Veletzky
Förderung
- Federal Ministry of Science, Research and Economy of Austria
- German Center for Infection research
- Bundesministerium für Wissenschaft, Forschung und Wirtschaft
- Deutsches Zentrum für Infektionsforschung
Zitieren
APA
Veletzky, L., Eberhardt, K. A., Hergeth, J., Stelzl, D. R., Zoleko Manego, R., Kreuzmair, R., Burger, G., Mischlinger, J., McCall, M. B. B., Mombo-Ngoma, G., Adegnika, A. A., Agnandji, S. T., Matsiegui, P. B., Lell, B., Kremsner, P., Mordmüller, B., Tappe, D., & Ramharter, M. (2024). Analysis of diagnostic test outcomes in a large loiasis cohort from an endemic region: Serological tests are often false negative in hyper-microfilaremic infections. PLOS Neglected Tropical Diseases. https://doi.org/10.1371/journal.pntd.0012054
Vancouver
Veletzky L, Eberhardt KA, Hergeth J, Stelzl DR, Zoleko Manego R, Kreuzmair R, et al. Analysis of diagnostic test outcomes in a large loiasis cohort from an endemic region: Serological tests are often false negative in hyper-microfilaremic infections. PLOS Neglected Tropical Diseases. 2024. doi:10.1371/journal.pntd.0012054
BibTeX
@article{Veletzky2024,
author = {Veletzky, Luzia and Eberhardt, Kirsten Alexandra and Hergeth, Jennifer and Stelzl, Daniel Robert and Zoleko Manego, Rella and Kreuzmair, Ruth and Burger, Gerrit and Mischlinger, Johannes and McCall, Matthew B B and Mombo-Ngoma, Ghyslain and Adegnika, Ayôla Akim and Agnandji, Selidji Todagbe and Matsiegui, Pierre Blaise and Lell, Bertrand and Kremsner, Peter and Mordmüller, Benjamin and Tappe, Dennis and Ramharter, Michael},
title = {Analysis of diagnostic test outcomes in a large loiasis cohort from an endemic region: Serological tests are often false negative in hyper-microfilaremic infections},
journal = {PLOS Neglected Tropical Diseases},
year = {2024},
doi = {10.1371/journal.pntd.0012054}
}
EUVIMED