A retrospective study of smart spot, a Bluetooth low‑energy real‑time location system supporting quality improvement efforts in Uganda
PLOS Digital Health · 03.11.2026 · 5 (11) · e0001790
DOI: 10.1371/journal.pdig.0001790 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 03.11.2026. Verfasst von Daniel Choi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, British Columbia, Canada. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grand Challenges Canada, Mining4Life, Michael Smith Health Research BC.
Abstract (Originalsprache)
Real-time location systems track assets and individuals, and in high-income clinical settings, they have improved patient flow. However, their use in low- and middle-income countries remains limited. Smart Spot, a low-cost Bluetooth low-energy real-time location system was integrated within the Smart Triage quality improvement platform in the outpatient department of Uganda Martyrs’ Hospital Ibanda. The primary objective was to evaluate whether Smart Spot data could be used to detect differences in time spent across clinical locations associated with Smart Triage implementation. The secondary objective was to assess the accuracy of Smart Spot data. At triage, children (or their caregivers) received a beacon attached to a lanyard. The beacons tracked patients’ locations throughout their time in the outpatient department. Smart Spot data were collected during a 4‑month baseline phase (pre-Smart Triage) and a 12‑month Smart Triage intervention phase. An algorithm was developed to reduce noise and generate more accurate records of each patient’s journey. The resulting pathways were compared to expected paths to evaluate Smart Spot’s accuracy. The median durations of patient time spent in specific areas were compared between phases using quantile regression. Data cleaning improved the matching to the expected patient flow from 13.0% to 73.1%. Compared with baseline, the median time patients spent in the assessment area decreased by 51.7% (-81.9 min; CI: -95.1 to -68.8), in the emergency room by 69.1% (-44.3 min; CI: -67.7 to -20.8), and total visit duration by 58.2% (-122.9 min; CI: -138.4 to -107.3), all with p-value < 0.001. Real-time location data supported the demonstration of the Smart Triage platform’s benefits. In the cleaned dataset, the intervention phase had shorter total visit time and time reductions within specific areas. Our evaluation demonstrates Smart Spot’s feasibility as an effective data-collection platform for quality improvement and its utility for retrospective analyses in low-resource settings.
Autor:innen und Institutionen
- Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, British Columbia, Canada.
- Institute for Global Health, BC Children's Hospital and BC Women's Hospital + Health Centre, Vancouver, British Columbia, Canada.
- Uganda Martyrs' Ibanda Hospital, Ibanda, Uganda.
- World Alliance for Lung and Intensive Care Medicine in Uganda, Kampala, Uganda.
- Uganda Catholic Medical Bureau, Kampala, Uganda.
ORCID-Profile: Daniel Choi, Charly Huxford, J Mark Ansermino, Dustin Dunsmuir
Förderung
- Grand Challenges Canada
- Mining4Life
- Michael Smith Health Research BC
- BC Children’s Hospital
- BC Children’s Hospital Foundation
Zitieren
APA
Choi, D., Tugume, E., Mwesigye, I., Ishebukara, A. I. A., Huxford, C., Pillay, Y., Tumubugane, G., Kenya-Mugisha, N., Kasyaba, R., Ansermino, J. M., Dunsmuir, D., & Pediatric Sepsis CoLab (2026). A retrospective study of smart spot, a Bluetooth low‑energy real‑time location system supporting quality improvement efforts in Uganda. PLOS Digital Health, 5(11), e0001790. https://doi.org/10.1371/journal.pdig.0001790
Vancouver
Choi D, Tugume E, Mwesigye I, Ishebukara AIA, Huxford C, Pillay Y, et al. A retrospective study of smart spot, a Bluetooth low‑energy real‑time location system supporting quality improvement efforts in Uganda. PLOS Digital Health. 2026;5(11):e0001790. doi:10.1371/journal.pdig.0001790
BibTeX
@article{Choi2026,
author = {Choi, Daniel and Tugume, Ediketh and Mwesigye, Isaac and Ishebukara, Aine Ivan Aye and Huxford, Charly and Pillay, Yashodani and Tumubugane, Gotharido and Kenya-Mugisha, Nathan and Kasyaba, Ronald and Ansermino, J Mark and Dunsmuir, Dustin and Pediatric Sepsis CoLab, Pediatric Sepsis CoLab},
title = {A retrospective study of smart spot, a Bluetooth low‑energy real‑time location system supporting quality improvement efforts in Uganda},
journal = {PLOS Digital Health},
year = {2026},
volume = {5},
number = {11},
pages = {e0001790},
doi = {10.1371/journal.pdig.0001790}
}