EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

STREAM: A data-driven framework for physiological state monitoring in ICU patients

STREAM: Ein datengestützter Rahmen für die Überwachung physiologischer Zustände bei ICU-Patient:innen

Ali Namvar iD, Sundaresh Ram, Wassim W Labaki, Stefanie Galban, Njira L Lugogo, Craig J Galban iD

PLOS Digital Health · 01.10.2026 · 5 (10) · e0001753

DOI: 10.1371/journal.pdig.0001753 ↗

Auf einen Blick

STREAM ordnet routinemäßige ICU-Daten fünf reproduzierbaren physiologischen Zuständen zu. Patient:innen mit „state outliers“ hatten eine deutlich höhere ICU-Mortalität.

Fragestellung

Kann STREAM aus kontinuierlichen physiologischen ICU-Daten interpretierbare Zustände ableiten und mit Mortalität verknüpfen?

Methode

Entwicklung mit eICU Collaborative Research Database (N = 158.294) und externe Validierung mit MIMIC-IV (N = 84.517). Analyse von 26 Routinemessungen mit Optimal-Transport-Theorie.

Ergebnisse

STREAM identifizierte fünf reproduzierbare physiologische Zustände. ICU-Mortalität bei state outliers: 37,6 % vs. 2,3 %; 16-fach höher. AUC: 0,863 nach 8 Stunden, 0,903 nach 72 Stunden; extern 0,798 bzw. 0,857.

Schlussfolgerung der Autor:innen

STREAM bietet eine transparente Überwachung datengeleiteter physiologischer Zustände und verknüpft Zustandsdynamik mit Outcome-Prognose. Die Autor:innen sehen Potenzial für eine prospektive Evaluation.

Kernaussagen

  • Fünf reproduzierbare physiologische Zustände wurden identifiziert
  • State outliers: 37,6 % ICU-Mortalität vs. 2,3 %
  • AUC 0,863 nach 8 Stunden und 0,903 nach 72 Stunden

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 01.10.2026. Verfasst von Ali Namvar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, Michigan, United States of America. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intensive care unit (ICU) monitoring systems face a critical gap: translating continuous physiological data into interpretable patterns that support clinical assessment. Existing approaches rely on static thresholds or severity scores that fail to capture dynamic disease progression patterns and provide limited insight into why patients change over time. We developed STREAM (State Trajectory Representation and Evolution-Aware Monitoring), which models each patient as a point in a multidimensional physiological space and applies geometric analysis of routine ICU data to track physiological instability. STREAM analyzes 26 routinely collected clinical measurements using optimal transport theory to discover data-derived physiological states without predefined categories and maps each patient to their nearest state. We evaluated STREAM using the multicenter eICU Collaborative Research Database (N = 158,294) for development and MIMIC-IV (N = 84,517) for external validation. STREAM identified five reproducible data-derived physiological states with distinct clinical signatures. Patients who spent less than 10% of their ICU stay within their expected state (state outliers) had ICU mortality of 37.6%, 16-fold higher than those who remained within their assigned states (2.3%). Mortality prediction achieved an area under the receiver operating characteristic curve of 0.863 at 8 hours and 0.903 at 72 hours, with excellent calibration (expected calibration error of 0.002). External validation on MIMIC-IV maintained robust performance (0.798 and 0.857, respectively), with state outliers exhibiting 10-fold higher mortality (33.5% vs. 3.2%). Feature importance analysis identified which laboratory values and vital signs are associated with movement toward higher-risk states, providing interpretable clinical explanations. STREAM provides transparent monitoring across data-derived physiological states, linking state dynamics with outcome prediction. Strong discrimination, calibration, and reproducibility across multicenter datasets support the method’s potential for prospective evaluation.

Autor:innen und Institutionen

  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, United States of America.
  • Department of Radiology and Imaging Sciences, Wallace H. Coulter Department of Biomedical Engineering, School of Electrical and Computer Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgi…
  • Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, United States of America.

ORCID-Profile: Ali Namvar, Craig J Galban

Zitieren

APA

Namvar, A., Ram, S., Labaki, W. W., Galban, S., Lugogo, N. L., & Galban, C. J. (2026). STREAM: A data-driven framework for physiological state monitoring in ICU patients. PLOS Digital Health, 5(10), e0001753. https://doi.org/10.1371/journal.pdig.0001753

Vancouver

Namvar A, Ram S, Labaki WW, Galban S, Lugogo NL, Galban CJ. STREAM: A data-driven framework for physiological state monitoring in ICU patients. PLOS Digital Health. 2026;5(10):e0001753. doi:10.1371/journal.pdig.0001753

BibTeX
@article{Namvar2026,
  author = {Namvar, Ali and Ram, Sundaresh and Labaki, Wassim W and Galban, Stefanie and Lugogo, Njira L and Galban, Craig J},
  title = {STREAM: A data-driven framework for physiological state monitoring in ICU patients},
  journal = {PLOS Digital Health},
  year = {2026},
  volume = {5},
  number = {10},
  pages = {e0001753},
  doi = {10.1371/journal.pdig.0001753}
}
Kostenlos starten →