EUVIMEDEUVIMED entdecken
Open Access · CC0

Using wearable sensors during the timed up and go and 6-minute walk test in Spinal Bulbar Muscular Atrophy

Kruthika Doreswamy, Henry Roberts, Angela Kokkinis, Galen Joe, Abdullah Alqahtani, Christopher Grunseich, Minal Jain iD

PLOS Digital Health · 13.05.2026 · 5 (5) · e0001416

DOI: 10.1371/journal.pdig.0001416 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 13.05.2026. Verfasst von Kruthika Doreswamy und 6 weiteren Autor:innen. Beteiligte Einrichtung: Rehabilitation Medicine Department, Clinical Center, National Institutes of Health,‌‌ Bethesda, Maryland, United States of America. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: National Institute of Neurological Disorders and Stroke.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spinal Bulbar Muscular Atrophy (SBMA) is a rare and slowly progressive disease that affects males. The Timed Up and Go (TUG) and 6-minute walk test (6MWT) are used in the clinic to track progression. Recent studies have used wearable sensors to track subtle changes in gait and balance in people with rare disease. The objective of this study was to determine whether inertial sensors could be used in men with SBMA to track changes in gait and balance. Our methods included ten participants with SBMA who completed the TUG and 6MWT while wearing six wearable sensors at the baseline, 6-month, and 12-month follow up visits. Our findings showed that this group of men did not progress in their disease over 12 months as evidenced by the stability of TUG durations, 6MWT distance, and sensor parameters. We observed strong associations between the sensor-derived parameters and both TUG duration and 6MWT distance. The sensors can be used during clinic assessments to measure gait and balance parameters. Further studies examining a larger sample size and at-home monitoring should be considered.

Autor:innen und Institutionen

  • Rehabilitation Medicine Department, Clinical Center, National Institutes of Health,‌‌ Bethesda, Maryland, United States of America.
  • National Institute of Neurological Disorders and Stroke, National Institutes of Health, ‌‌Bethesda, Maryland, United States of America.

ORCID-Profile: Minal Jain

Förderung

  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Doreswamy, K., Roberts, H., Kokkinis, A., Joe, G., Alqahtani, A., Grunseich, C., & Jain, M. (2026). Using wearable sensors during the timed up and go and 6-minute walk test in Spinal Bulbar Muscular Atrophy. PLOS Digital Health, 5(5), e0001416. https://doi.org/10.1371/journal.pdig.0001416

Vancouver

Doreswamy K, Roberts H, Kokkinis A, Joe G, Alqahtani A, Grunseich C, et al. Using wearable sensors during the timed up and go and 6-minute walk test in Spinal Bulbar Muscular Atrophy. PLOS Digital Health. 2026;5(5):e0001416. doi:10.1371/journal.pdig.0001416

BibTeX
@article{Doreswamy2026,
  author = {Doreswamy, Kruthika and Roberts, Henry and Kokkinis, Angela and Joe, Galen and Alqahtani, Abdullah and Grunseich, Christopher and Jain, Minal},
  title = {Using wearable sensors during the timed up and go and 6-minute walk test in Spinal Bulbar Muscular Atrophy},
  journal = {PLOS Digital Health},
  year = {2026},
  volume = {5},
  number = {5},
  pages = {e0001416},
  doi = {10.1371/journal.pdig.0001416}
}
Kostenlos starten →