EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical validation of a novel hand dexterity measurement device

Conor D Hayden iD, Bruce P Murphy, Deirdre Gilsenan, Bahman Nasseroleslami, Orla Hardiman, Deirdre Murray

PLOS Digital Health · 10.03.2025 · 4 (3) · e0000744

DOI: 10.1371/journal.pdig.0000744 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 10.03.2025. Verfasst von Conor D Hayden und 5 weiteren Autor:innen. Beteiligte Einrichtung: Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Research Board, Research Motor Neurone, Higher Education Authority.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lack of sensitive objective outcome measures for hand dexterity is a barrier for clinical assessment of neurological conditions and has negatively affected clinical trials. Here, we clinically validate a new method for measuring hand dexterity, a novel hand worn sensor that digitises the Finger Tapping Test. The device was assessed in a cohort of 180 healthy controls and 51 people with Amyotrophic Lateral Sclerosis (ALS) and compared against rating scales and traditional measures (Nine Hole Peg test and grip dynamometry). 14 features were extracted from the device and using a logistic regression algorithm, a 0-100 dexterity performance score was generated for each participant, which accounted for age/sex differences. The device returned objective ratings of a participant’s hand dexterity (dominant, non-dominant and overall score). The average overall dexterity performance score in all healthy participants was 88 ± 17 (mean ± standard deviation). The overall dexterity score was statistically significantly worse in participants with ALS (age/sex matched healthy subset: 80 ± 20, ALS: 45 ± 32, p-value < 0.0001). The device also had a higher completion rate, (94% dominant hand) compared to the traditional measures (82% dominant hand). This test and scoring system have been validated and the regression model was developed using a framework that is potentially applicable to any relevant condition. This device could act as an objective outcome measure in clinical trials and may be useful in improving patient care.

Autor:innen und Institutionen

  • Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland.
  • Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland.
  • Academic Unit of Neurology, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland.
  • Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin, Ireland.
  • Neurocent Directorate, Beaumont Hospital, Beaumont, Dublin, Ireland.

ORCID-Profile: Conor D Hayden

Förderung

  • Health Research Board
  • Research Motor Neurone
  • Higher Education Authority

Zitieren

APA

Hayden, C. D., Murphy, B. P., Gilsenan, D., Nasseroleslami, B., Hardiman, O., & Murray, D. (2025). Clinical validation of a novel hand dexterity measurement device. PLOS Digital Health, 4(3), e0000744. https://doi.org/10.1371/journal.pdig.0000744

Vancouver

Hayden CD, Murphy BP, Gilsenan D, Nasseroleslami B, Hardiman O, Murray D. Clinical validation of a novel hand dexterity measurement device. PLOS Digital Health. 2025;4(3):e0000744. doi:10.1371/journal.pdig.0000744

BibTeX
@article{Hayden2025,
  author = {Hayden, Conor D and Murphy, Bruce P and Gilsenan, Deirdre and Nasseroleslami, Bahman and Hardiman, Orla and Murray, Deirdre},
  title = {Clinical validation of a novel hand dexterity measurement device},
  journal = {PLOS Digital Health},
  year = {2025},
  volume = {4},
  number = {3},
  pages = {e0000744},
  doi = {10.1371/journal.pdig.0000744}
}
Kostenlos starten →