EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Determinants of photoplethysmography signal quality at the wrist

Peter H Charlton iD, Vaidotas Marozas, Elisa Mejía-Mejía, Panicos A Kyriacou, Jonathan Mant

PLOS Digital Health · 27.06.2025 · 4 (6) · e0000585

DOI: 10.1371/journal.pdig.0000585 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 27.06.2025. Verfasst von Peter H Charlton und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation, European Partnership on Metrology, Innovate UK.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wrist photoplethysmogram (PPG) signals are widely used for physiological monitoring in consumer devices. However, the PPG is highly susceptible to noise, which can reduce the accuracy of monitored parameters. The aim of this study was to identify factors which influence PPG signal quality. Data from the Aurora-BP dataset were used, consisting of reflectance wrist PPG signals measured from 1,142 subjects of varying ages and health statuses. Measurements were acquired in supine, sitting, and standing postures, and with the sensor held at different heights. Three signal quality metrics were calculated: the signal-to-noise ratio (SNR), the perfusion index (PI), and the template-matching correlation coefficient (TMCC). When comparing between postures with the sensor held at a natural height, quality was greatest in the supine position (SNR: 18.6 dB), followed by sitting with the arm resting in the lap (13.7 dB), and lowest whilst standing with the arm hanging alongside (9.0 dB) (p < 0.001). Signal quality increased as the arm was raised to heart height: whilst sitting, quality was lowest with the arm alongside the body (10.5 dB), and increased when the sensor was held in the lap (13.7 dB) and at heart height (15.5 dB) (p < 0.001). Similar trends were observed for the TMCC and PI. Findings were mixed for the influence of participant characteristics on signal quality. The SNR and TMCC, but not the PI, increased with age. The SNR either decreased or remained constant at darker skin tones when controlling for PPG DC amplitude, compared to constant or increased when allowing DC amplitude to vary. In conclusion, this study identified the impacts of posture and sensor height on signal quality, with highest qualities observed in the supine posture and with the sensor at heart height. It also highlights the importance of adjusting LED light intensity to maintain signal quality across skin tones.

Autor:innen und Institutionen

  • Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
  • Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom.
  • Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania.
  • Faculty of Electrical and Electronics Engineering, Kaunas University of Technology, Kaunas, Lithuania.
  • Rush Alzheimer's Disease Center, Rush University Medical Center, Chicago, Illinois, United States of America.

ORCID-Profile: Peter H Charlton

Förderung

  • British Heart Foundation
  • European Partnership on Metrology
  • Innovate UK

Zitieren

APA

Charlton, P. H., Marozas, V., Mejía-Mejía, E., Kyriacou, P. A., & Mant, J. (2025). Determinants of photoplethysmography signal quality at the wrist. PLOS Digital Health, 4(6), e0000585. https://doi.org/10.1371/journal.pdig.0000585

Vancouver

Charlton PH, Marozas V, Mejía-Mejía E, Kyriacou PA, Mant J. Determinants of photoplethysmography signal quality at the wrist. PLOS Digital Health. 2025;4(6):e0000585. doi:10.1371/journal.pdig.0000585

BibTeX
@article{Charlton2025,
  author = {Charlton, Peter H and Marozas, Vaidotas and Mejía-Mejía, Elisa and Kyriacou, Panicos A and Mant, Jonathan},
  title = {Determinants of photoplethysmography signal quality at the wrist},
  journal = {PLOS Digital Health},
  year = {2025},
  volume = {4},
  number = {6},
  pages = {e0000585},
  doi = {10.1371/journal.pdig.0000585}
}
Kostenlos starten →