A methodology to reduce the localization error in multi-loci microscopy provides new insights into enhancer biology
PLOS Computational Biology · 2025
DOI: 10.1371/journal.pcbi.1013796 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Computational Biology, 2025. Verfasst von Christopher H Bohrer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Receptor Biology and Gene Expression, National Institutes of Health, Bethesda, Maryland, United States of America. Hauptthemen laut MEDLINE: Enhancer Elements, Genetic, Microscopy, Image Processing, Computer-Assisted. Die Arbeit nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC0). Gefördert von: National Institutes of Health.
Abstract (Originalsprache)
Numerous functions hinge on the spatial arrangement of different genomic loci. Hence, microscopy techniques, such as chromatin tracing, have been developed to localize multiple loci in fixed cells. Depending on the throughput and specifics of the experiment, localization errors can still obscure the true spatial locations. We have developed a post-processing methodology to address this challenge without the need for additional experimentation: Loci Enabled Advanced Resolution (LEAR). By leveraging the fact that localization errors increase the variability of the displacements between loci, and given an approximation of the localization error, we can approximate the ground truth spatial variation for each pair of loci to guide an iterative error correction process. After validating our approach with simulation and experiment, we then applied our approach to existing chromatin tracing data that probed the relation between chromatin organization and Sox2 regulation, where previous work found no clear correlation between enhancer-promoter proximity and transcription bursts in individual cells. We discovered a correlation previously obscured by localization error, clearly demonstrating the need for the methodology. We then investigated the influence of loop-extrusion on higher order multi-way contact frequencies, which dramatically increased with the application of the LEAR method, finding that certain multi-way contacts were only present with loop-extrusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Laboratory of Receptor Biology and Gene Expression, National Institutes of Health, Bethesda, Maryland, United States of America.
ORCID-Profile: Daniel R Larson
Förderung
- National Institutes of Health
Zitieren
APA
Bohrer, C. H., & Larson, D. R. (2025). A methodology to reduce the localization error in multi-loci microscopy provides new insights into enhancer biology. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1013796
Vancouver
Bohrer CH, Larson DR. A methodology to reduce the localization error in multi-loci microscopy provides new insights into enhancer biology. PLOS Computational Biology. 2025. doi:10.1371/journal.pcbi.1013796
BibTeX
@article{Bohrer2025,
author = {Bohrer, Christopher H and Larson, Daniel R},
title = {A methodology to reduce the localization error in multi-loci microscopy provides new insights into enhancer biology},
journal = {PLOS Computational Biology},
year = {2025},
doi = {10.1371/journal.pcbi.1013796}
}
EUVIMED