Simulation of 69 microbial communities indicates sequencing depth and false positives are major drivers of bias in prokaryotic metagenome-assembled genome recovery
PLOS Computational Biology · 2024
DOI: 10.1371/journal.pcbi.1012530 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Computational Biology, 2024. Verfasst von Ulisses Rocha und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Microbial Ecology, Helmholtz Center for Environmental Research-UFZ, Leipzig, Germany. Hauptthemen laut MEDLINE: Metagenome, Microbiota, Computer Simulation. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helmholtz Young Investigator grant, Deutsche Forschungsgemeinschaft (DFG, German Research Foundation), São Paulo Research Foundation (FAPESP).
Abstract (Originalsprache)
We hypothesize that sample species abundance, sequencing depth, and taxonomic relatedness influence the recovery of metagenome-assembled genomes (MAGs). To test this hypothesis, we assessed MAG recovery in three in silico microbial communities composed of 42 species with the same richness but different sample species abundance, sequencing depth, and taxonomic distribution profiles using three different pipelines for MAG recovery. The pipeline developed by Parks and colleagues (8K) generated the highest number of MAGs and the lowest number of true positives per community profile. The pipeline by Karst and colleagues (DT) showed the most accurate results (~ 92%), outperforming the 8K and Multi-Metagenome pipeline (MM) developed by Albertsen and collaborators. Sequencing depth influenced the accurate recovery of genomes when using the 8K and MM, even with contrasting patterns: the MM pipeline recovered more MAGs found in the original communities when employing sequencing depths up to 60 million reads, while the 8K recovered more true positives in communities sequenced above 60 million reads. DT showed the best species recovery from the same genus, even though close-related species have a low recovery rate in all pipelines. Our results highlight that more bins do not translate to the actual community composition and that sequencing depth plays a role in MAG recovery and increased community resolution. Even low MAG recovery error rates can significantly impact biological inferences. Our data indicates that the scientific community should curate their findings from MAG recovery, especially when asserting novel species or metabolic traits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Applied Microbial Ecology, Helmholtz Center for Environmental Research-UFZ, Leipzig, Germany.
- Department of Computer Science, Federal University of Technology-Paraná, UTFPR, Cornélio Procópio, Brazil.
ORCID-Profile: Ulisses Rocha, Joao Pedro Saraiva
Förderung
- Helmholtz Young Investigator grant
- Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)
- São Paulo Research Foundation (FAPESP)
- Helmholtz-Gemeinschaft
- FAPESP
Zitieren
APA
Rocha, U., Kasmanas, J. C., Toscan, R., Sanches, D. S., Magnusdottir, S., & Saraiva, J. P. (2024). Simulation of 69 microbial communities indicates sequencing depth and false positives are major drivers of bias in prokaryotic metagenome-assembled genome recovery. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1012530
Vancouver
Rocha U, Kasmanas JC, Toscan R, Sanches DS, Magnusdottir S, Saraiva JP. Simulation of 69 microbial communities indicates sequencing depth and false positives are major drivers of bias in prokaryotic metagenome-assembled genome recovery. PLOS Computational Biology. 2024. doi:10.1371/journal.pcbi.1012530
BibTeX
@article{Rocha2024,
author = {Rocha, Ulisses and Kasmanas, Jonas Coelho and Toscan, Rodolfo and Sanches, Danilo S and Magnusdottir, Stefania and Saraiva, Joao Pedro},
title = {Simulation of 69 microbial communities indicates sequencing depth and false positives are major drivers of bias in prokaryotic metagenome-assembled genome recovery},
journal = {PLOS Computational Biology},
year = {2024},
doi = {10.1371/journal.pcbi.1012530}
}
EUVIMED