Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework

Tianai Wang iD, Christine Quast, Florian Bönner, Malte Kelm, Tobias Zeus, Teresa Lemainque iD, Ulrich Steinseifer, Michael Neidlin

PLOS Computational Biology · 27.03.2025 · 21 (3) · e1012467

DOI: 10.1371/journal.pcbi.1012467 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Computational Biology, online erschienen am 27.03.2025. Verfasst von Tianai Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Models, Cardiovascular, Magnetic Resonance Imaging, Hemodynamics. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft (DFG, German Research Foundation), Studienstiftung des Deutschen Volkes (German Academic Scholarship Foundation), Joachim Herz Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aortic stenosis (AS) leads to alterations of supra-valvular flow patterns which can cause increased damage of red blood cell (RBC) membranes. We investigated these patient specific patterns of a severe AS patient and their reversal in healthy flow through a 4D Flow MRI-based CFD methodology. Computational models of subject-specific aortic geometries were created using in-vivo medical imaging data. Temporally and spatially resolved boundary conditions derived from 4D Flow MRI were implemented for an AS patient and a healthy subject. After validation of the in-silico results with in-vivo data, a healthy inflow profile was set for the AS patient in the CFD model. Pathological versus healthy flow fields were compared regarding their blood flow characteristics, i.e., shear stresses on RBCs and helicity. The accuracy of the 4D Flow MRI-based CFD model was proven with excellent agreement between in-vivo and in-silico velocity fields and R² = 0.9. A pathological high shear stress region in the bulk flow was present during late systole with an increase of 125% compared to both healthy flow. The physiological bihelical structure with predominantly right-handed helices vanished for the pathological state. Instead, a left-handed helix appeared, accompanied by an overall increase in turbulent kinetic energy in areas of accumulated left-handed helicity. The validated 4D Flow MRI-based CFD model identified marked differences between AS and healthy flow. It suggests that altered turbulent and helical structures in the bulk flow are the cause for increased, potentially damaging forces acting upon RBCs in AS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisModels, CardiovascularMagnetic Resonance ImagingHemodynamicsHumansComputer SimulationBlood Flow VelocityMaleFemaleImaging, Three-DimensionalAortaAgedComputational Biology

Autor:innen und Institutionen

  • Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
  • Department of Cardiology, Pulmonary Diseases and Vascular Medicine, Heinrich-Heine University, Düsseldorf, Germany.
  • CARID, Cardiovascular Research Institute Düsseldorf, Heinrich-Heine University, Düsseldorf, Germany.
  • Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Aachen, Germany.

ORCID-Profile: Tianai Wang, Teresa Lemainque

Förderung

  • Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)
  • Studienstiftung des Deutschen Volkes (German Academic Scholarship Foundation)
  • Joachim Herz Foundation
  • Joachim Herz Stiftung

Zitieren

APA

Wang, T., Quast, C., Bönner, F., Kelm, M., Zeus, T., Lemainque, T., Steinseifer, U., & Neidlin, M. (2025). Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework. PLOS Computational Biology, 21(3), e1012467. https://doi.org/10.1371/journal.pcbi.1012467

Vancouver

Wang T, Quast C, Bönner F, Kelm M, Zeus T, Lemainque T, et al. Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework. PLOS Computational Biology. 2025;21(3):e1012467. doi:10.1371/journal.pcbi.1012467

BibTeX
@article{Wang2025,
  author = {Wang, Tianai and Quast, Christine and Bönner, Florian and Kelm, Malte and Zeus, Tobias and Lemainque, Teresa and Steinseifer, Ulrich and Neidlin, Michael},
  title = {Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework},
  journal = {PLOS Computational Biology},
  year = {2025},
  volume = {21},
  number = {3},
  pages = {e1012467},
  doi = {10.1371/journal.pcbi.1012467}
}
Kostenlos starten →