Model-based analysis of the acute effects of transcutaneous magnetic spinal cord stimulation on micturition after spinal cord injury in humans

Mahshid Fardadi iD, J C Leiter, Daniel C Lu, Tetsuya Iwasaki iD

PLOS Computational Biology · 2024

DOI: 10.1371/journal.pcbi.1012237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Computational Biology, 2024. Verfasst von Mahshid Fardadi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of California, Los Angeles, California, United States of America. Hauptthemen laut MEDLINE: Spinal Cord Injuries, Urination. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Defense (DOD), University of California Chancellor’s Postdoctoral Fellowship and from the Louis and Harold Price Foundation, H & H Evergreen Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

After spinal cord injuries (SCIs), patients may develop either detrusor-sphincter dyssynergia (DSD) or urinary incontinence, depending on the level of the spinal injury. DSD and incontinence reflect the loss of coordinated neural control among the detrusor muscle, which increases bladder pressure to facilitate urination, and urethral sphincters and pelvic floor muscles, which control the bladder outlet to restrict or permit bladder emptying. Transcutaneous magnetic stimulation (TMS) applied to the spinal cord after SCI reduced DSD and incontinence. We defined, within a mathematical model, the minimum neuronal elements necessary to replicate neurogenic dysfunction of the bladder after a SCI and incorporated into this model the minimum additional neurophysiological features sufficient to replicate the improvements in bladder function associated with lumbar TMS of the spine in patients with SCI.

Methods

We created a computational model of the neural circuit of micturition based on Hodgkin-Huxley equations that replicated normal bladder function. We added interneurons and increased network complexity to reproduce dysfunctional micturition after SCI, and we increased the density and complexity of interactions of both inhibitory and excitatory lumbar spinal interneurons responsive to TMS to provide a more diverse set of spinal responses to intrinsic and extrinsic activation of spinal interneurons that remains after SCI.

Results

The model reproduced the re-emergence of a spinal voiding reflex after SCI. When we investigated the effect of monophasic and biphasic TMS at two frequencies applied at or below T10, the model replicated the improved coordination between detrusor and external urethral sphincter activity that has been observed clinically: low-frequency TMS (1 Hz) within the model normalized control of voiding after SCI, whereas high-frequency TMS (30 Hz) enhanced urine storage.

Conclusion

Neuroplasticity and increased complexity of interactions among lumbar interneurons, beyond what is necessary to simulate normal bladder function, must be present in order to replicate the effects of SCI on control of micturition, and both neuronal and network modifications of lumbar interneurons are essential to understand the mechanisms whereby TMS reduced bladder dysfunction after SCI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal Cord InjuriesUrinationHumansModels, NeurologicalSpinal Cord StimulationUrinary BladderComputer SimulationComputational BiologySpinal Cord

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of California, Los Angeles, California, United States of America.
  • White River Junction VA Medical Center, White River Junction, Vermont, United States of America.
  • Department of Neurosurgery, University of California, Los Angeles, California, United States of America.

ORCID-Profile: Mahshid Fardadi, Tetsuya Iwasaki

Förderung

  • Department of Defense (DOD)
  • University of California Chancellor’s Postdoctoral Fellowship and from the Louis and Harold Price Foundation
  • H & H Evergreen Foundation
  • Jonathan and Susan Dolgen Foundation

Zitieren

APA

Fardadi, M., Leiter, J. C., Lu, D. C., & Iwasaki, T. (2024). Model-based analysis of the acute effects of transcutaneous magnetic spinal cord stimulation on micturition after spinal cord injury in humans. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1012237

Vancouver

Fardadi M, Leiter JC, Lu DC, Iwasaki T. Model-based analysis of the acute effects of transcutaneous magnetic spinal cord stimulation on micturition after spinal cord injury in humans. PLOS Computational Biology. 2024. doi:10.1371/journal.pcbi.1012237

BibTeX
@article{Fardadi2024,
  author = {Fardadi, Mahshid and Leiter, J C and Lu, Daniel C and Iwasaki, Tetsuya},
  title = {Model-based analysis of the acute effects of transcutaneous magnetic spinal cord stimulation on micturition after spinal cord injury in humans},
  journal = {PLOS Computational Biology},
  year = {2024},
  doi = {10.1371/journal.pcbi.1012237}
}
Kostenlos starten →